Lapas attēli
PDF
ePub

Postoperational and Storage Task 5: Inside Postoperational Tasks.

Remove and inspect MILES inside cables. See Inside Tasks 12 and 13.

Remove battery box. Remove batteries from battery box and inspect battery box. See Inside Tasks 4 and 5.

Remove and inspect control console. See Inside Tasks 2 and 3.

NOTE

Reinstall original M1 Abrams Tank bolts, nuts and lock
washers in tank support plate.

Remove and inspect main gun/coax MG transmitter. See Inside Task 8 and 9.
Remove and inspect coax microphone assembly. See Inside Tasks 6 and 7.

Postoperational and Storage Task 6: Outside Postoperational Tasks.
Remove and inspect CVKI cable assembly. See Outside Tasks 11 and 12.
Remove and inspect Hoffman 10-pole cable assembly. See Outside Task 15.

Remove and inspect CVKI. See Outside Task 9.

Remove and inspect detector belt segments and wedge mounting blocks. Leave fastener tape on the vehicle. See Outside Tasks 5, 6, 7, and 8.

Remove, inspect, and service Hoffman device simulator body with mount. See Outside Task 13.

NOTE

Reinstall periscope window in loader's hatch.

Reinstall Hoffman device 10-pole socket dust cap.

Postoperational and Storage Task 7: Transit Case Packing Instructions.

[merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][merged small][ocr errors][merged small][merged small][merged small][merged small]

Replace all MILES equipment in M1 transit case. Make sure each piece is in proper space. Use transmit case orientation plate on case lid as a guide.

Close and latch the case.

MI

Postoperational and Storage Task 8: Return Equipment.

Return all equipment to your NCOIC.

Include: All MILES equipment.

Hoffman device system

Blank fire adapters and blank ammunition trays

Unused blank ammunition

Unused Hoffman device cartridges

Special tools

CHAPTER 3

MAINTENANCE INSTRUCTIONS

SECTION I. LUBRICATION INSTRUCTIONS

MILES equipment for the M1 Abrams Tank requires no operator lubrication.

SECTION II. TROUBLESHOOTING

Table 3-1 lists the common malfunctions which you may find during the operation or maintenance of the MILES simulator system for the M1 Abrams Tank or its components. You should perform the tests/inspections and corrective actions in the order listed.

This manual cannot list all malfunctions that may occur, nor all tests or inspections and corrective actions. If a malfunction is not listed or is not corrected by listed corrective actions, notify your supervisor.

Table 3-1. Troubleshooting

MALFUNCTION

TEST OR INSPECTION

CORRECTIVE ACTION

M2 MACHINE GUN

1. FIRING LIGHT ON M2 LASER TRANSMITTER DOES NOT OPERATE

Step 1. Check battery.

Wait 10 seconds, replace battery and retest.

Step 2. If still no light.

Report on DA Form 2404 and replace transmitter.

2.

M240 MACHINE GUN

FIRING LIGHT ON M240 MG LASER TRANSMITTER DOES NOT OPERATE

Step 1. Check battery.

Wait 10 seconds, replace battery and retest.

Step 2. If still no light.

Report on DA Form 2404 and replace transmitter.

MWLD EQUIPMENT

3. NO ALARM ON MWLD TORSO HARNESS UPON INSERTING BATTERY

Step 1. Remove battery.

Wait 10 seconds, reinsert battery and retest.

Step 2. If still no alarm.

Replace battery and retest.

Step 3. If still no alarm.

Report on DA form 2404 and replace torso harness.

« iepriekšējāTurpināt »