Code of Federal Regulations: Title 21: Food and DrugsU.S. Government Printing Office, 2005 - 792 lappuses Official U.S. Government edition. Code of Federal Regulations, Title 21, Food and Drugs, Pt. 800-1299, Revised as of April 1, 2005. Title 21-Food and Drugs is composed of nine volumes. The parts in these volumes are arranged in the following order: Parts 1-99, 100-169, 170-199, 200-299, 300-499, 500-599, 600-799, 800-1299 an 1300 to end. The fires eight volumes, containing parts 1-1299, comprise Chapter I - Food and Drug Administration, Department of Health and Human Services. The ninth volume, containing part 1300 to end, includes Chapter II - Drug Enforcement Administration, Department of Justice and Chapter III - Office of National Drug Control Policy. The contents of these volumes represent all current regulations codified under this title of the CFR as of April 1, 2005. |
No grāmatas satura
1.–3. rezultāts no 78.
313. lappuse
... tube cuff . ( a ) Identification . An inflatable tra- cheal tube cuff is a device used to pro- vide an airtight seal between a tra- cheal tube and a patient's trachea . ( b ) Classification . Class II ( perform- ance standards ) ...
... tube cuff . ( a ) Identification . An inflatable tra- cheal tube cuff is a device used to pro- vide an airtight seal between a tra- cheal tube and a patient's trachea . ( b ) Classification . Class II ( perform- ance standards ) ...
627. lappuse
... tube current for the maximum- rated continuous tube current for the naximum - rated peak tube potential . Light field means that area of the ntersection of the light beam from the Deam - limiting device and one of the set of planes ...
... tube current for the maximum- rated continuous tube current for the naximum - rated peak tube potential . Light field means that area of the ntersection of the light beam from the Deam - limiting device and one of the set of planes ...
628. lappuse
... tube potential in kV and number of x - ray pulses ; ( 3 ) For CT equipment designed for pulsed operation , peak tube potential in kV , scan time in seconds , and either tube current in milliamperes ( mA ) , x- ray pulse width in seconds ...
... tube potential in kV and number of x - ray pulses ; ( 3 ) For CT equipment designed for pulsed operation , peak tube potential in kV , scan time in seconds , and either tube current in milliamperes ( mA ) , x- ray pulse width in seconds ...
Saturs
ADMINISTRATION DEPARTMENT OF HEALTH | 5 |
801 | 13 |
803 | 38 |
Autortiesības | |
40 citas sadaļas nav parādītas.
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
AC-powered accessories accreditation body amended at 65 ance standards application blood cardiopulmonary bypass catheter chapter subject Class II perform Class II special Classification clinical clude commercial distribution complaint files component current good manufacturing Date PMA dental denture device includes device intended device is exempt device that consists disease electronic equipment evaluation FDA's Food and Drug guidance document Identification immunological test system implanted intended for medical intended to measure investigation joint July 25 labeling limitations mammography manufacturing practice manufacturing practice regula means medical purposes ment monitor notice of completion paragraph patient PDP is required plasma PMA or notice postmarket surveillance premarket approval premarket notification procedures procedures in subpart prosthesis radiation regulation requirements concerning records respect to complaint Sept serum special controls specific submit subpart E surgical tion tissue trols tube type of device user facility vice