Validation in Chemical MeasurementPaul De Bièvre, Helmut Günzler Springer Science & Business Media, 2005. gada 6. dec. - 168 lappuses The validation of analytical methods is based on the characterisation of a measurement procedure (selectivity, sensitivity, repeatability, reproducibility). This volume collects 31 outstanding papers on the topic, mostly published in the period 2000-2003 in the journal "Accreditation and Quality Assurance." They provide the latest understanding, and possibly the rationale why it is important to integrate the concept of validation into the standard procedures of every analytical laboratory. In addition, this anthology considers the benefits to both: the analytical laboratory and the user of the measurement results. |
No grāmatas satura
1.–5. rezultāts no 86.
. lappuse
... laboratory . It is hoped that this anthology is of benefit to both the producers and the users of results of chemical measurements : the basic concepts and the basic thinking in measurement are the same for both . Prof. Dr. P. De Bièvre ...
... laboratory . It is hoped that this anthology is of benefit to both the producers and the users of results of chemical measurements : the basic concepts and the basic thinking in measurement are the same for both . Prof. Dr. P. De Bièvre ...
. lappuse
... laboratory protocol................................. 84 14 Qualification and validation of software and computer systems in laboratories. Part 1: Validation during development....................................... The evaluation of ...
... laboratory protocol................................. 84 14 Qualification and validation of software and computer systems in laboratories. Part 1: Validation during development....................................... The evaluation of ...
. lappuse
... Laboratory of Israel , Dancinger A. Bldg . , Givat Ram , Jerusalem 91904 , Israel Elke Anklam European Commission , Directorate General Joint Research Centre , Institute for Reference Materials and Measurements , Food Safety and Quality ...
... Laboratory of Israel , Dancinger A. Bldg . , Givat Ram , Jerusalem 91904 , Israel Elke Anklam European Commission , Directorate General Joint Research Centre , Institute for Reference Materials and Measurements , Food Safety and Quality ...
. lappuse
... Laboratory Centre Celje , Tkalska 15 , SI - 3000 Celje , Slovenia Hans H. Maurer Department of Experimental and Clinical Toxicology , Institute of Experimental and Clinical Pharmacology and Toxicology , University of Saarland , 66421 ...
... Laboratory Centre Celje , Tkalska 15 , SI - 3000 Celje , Slovenia Hans H. Maurer Department of Experimental and Clinical Toxicology , Institute of Experimental and Clinical Pharmacology and Toxicology , University of Saarland , 66421 ...
4. lappuse
... laboratories. Unfortunately, some authors also used the term repro- ducibility for within-laboratory studies at the level of in- termediate precision [8, 12]. This should, however, be avoided in order to prevent confusion. As already ...
... laboratories. Unfortunately, some authors also used the term repro- ducibility for within-laboratory studies at the level of in- termediate precision [8, 12]. This should, however, be avoided in order to prevent confusion. As already ...
Saturs
1 | |
10 | |
Clinical reference materials for the validation of | 31 |
Qualification and validation of software and computer | 42 |
Validation of the uncertainty evaluation for | 63 |
Validation criteria for developing ionselective | 73 |
quality assurance | 148 |
Is the estimation of measurement uncertainty a viable | 155 |
Different approaches to legal requirements | 159 |
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
acceptance Accred Qual Assur accuracy Anal analysis analyte concentration analytical chemistry analytical measurement analytical method analytical procedure Anklam AOAC AOAC INTERNATIONAL application assessment bias calculated calibration curve capillary cation certified certified reference materials Chem chemical clinical components computer systems corrosion criteria CRMs defined detector determination documentation drug EURACHEM evaluation experimental factors functions Hewlett-Packard HPLC injection installation instrument interlaboratory International laboratory linearity LLOQ matrix measurement uncertainty ment meth method validation Metrology mmol/l obtained operating parameters peak performance pharmaceutical phase precision protocol qualification quality assurance quantitative quinizarin range recovery reference materials relative standard deviation reliability reproducibility requirements ruggedness testing sample scope of accreditation solution solvent red 24 solvent yellow 124 specifications Springer-Verlag standard deviation Table tainty test methods tion trueness type of tests uncer uncertainty associated uncertainty estimation vali vendor verification Waldbronn