Operator's and Organizational Maintenance Manual (including Repair Parts and Special Tools List): Mortar Ballistics Computer Set, M23 (1220-01-119-6049).Headquarters, Department of the Army, 1985 |
No grāmatas satura
1.–5. rezultāts no 24.
2-1. lappuse
... SEQUENCE INDICATOR BATT LOW INDICATOR ACTION SWITCHES- DATA ENTRY , COMPUTATION , JKL MNO REVIEW AND END RE- BACK FIRE MISSIONS VIEW 2 ABC DEF OHI SURV CLEAR ENTRY BATT LOW Ꮕ FIRE MISSION MON EOM XMIT COMPUTE SWITCHES- FIRE MISSION ...
... SEQUENCE INDICATOR BATT LOW INDICATOR ACTION SWITCHES- DATA ENTRY , COMPUTATION , JKL MNO REVIEW AND END RE- BACK FIRE MISSIONS VIEW 2 ABC DEF OHI SURV CLEAR ENTRY BATT LOW Ꮕ FIRE MISSION MON EOM XMIT COMPUTE SWITCHES- FIRE MISSION ...
2-4. lappuse
... sequence through data ) . Starts message to observer ( MTO ) menus or command message to observer ( CMD ) menus for entry and transmission of fir- ing information to the observer . Removes last ( rightmost ) character from a data field ...
... sequence through data ) . Starts message to observer ( MTO ) menus or command message to observer ( CMD ) menus for entry and transmission of fir- ing information to the observer . Removes last ( rightmost ) character from a data field ...
2-11. lappuse
... sequence indicator 39 ( LED ) 40 BATT LOW indicator ( LED ) 41 message indicator ( LED ) audio alarm Indicates display timeout period has expired ( when flashing ) . Flashes once every 6 seconds while display is timed out . Stays on ...
... sequence indicator 39 ( LED ) 40 BATT LOW indicator ( LED ) 41 message indicator ( LED ) audio alarm Indicates display timeout period has expired ( when flashing ) . Flashes once every 6 seconds while display is timed out . Stays on ...
2-18. lappuse
... Sequence indicator flashes indicating additional selections to be viewed . 23 Press SEQ switch bringing additional selections to display . ( Sequence indicator 208 315 412 418 is off . ) display switch > 2 < 24 Press display switch 2 to ...
... Sequence indicator flashes indicating additional selections to be viewed . 23 Press SEQ switch bringing additional selections to display . ( Sequence indicator 208 315 412 418 is off . ) display switch > 2 < 24 Press display switch 2 to ...
2-36. lappuse
... indicators ( DSP ) , and the modem ( MOD ) . These four tests may be performed in any sequence , but are presented here in the following order MICR , SW , DSP , and MOD . 1 SELF - TEST ( CONT ) DISPLAY Press ON 2-36 TM 9-1220-246-12 & P.
... indicators ( DSP ) , and the modem ( MOD ) . These four tests may be performed in any sequence , but are presented here in the following order MICR , SW , DSP , and MOD . 1 SELF - TEST ( CONT ) DISPLAY Press ON 2-36 TM 9-1220-246-12 & P.
Bieži izmantoti vārdi un frāzes
ABBREVIATIONS AND WORDS ACTION altitude azimuth Ballistics base piece Check CKFR Column connector continuing the mission coordinates DATA ENTRY DATA switch Deflection and charge direction and numeric DISPLAY ABBREVIATIONS DISPLAY Press SEQ entered by computer equipment ERROR MESSAGE field wire final protective fire fire for effect Fire line violation FIRE LN VIOL Fire request FIRE ZONES Fuze setting Grid Fire Mission higher maintenance level INITIALIZATION CONT INPUT MISSIONS CONT known point KNPT KNPT/TGT LEGAL ENTRIES MANUAL INPUT MISSIONS manually entered meters MICR mils Mission and target multiple choice entry National Stock Number number entered numeric entry obtained before continuing operation PMCS Press COMPUTE switch Press SEQ switch Proper clearance radio registration point Repair safety fan Section SELF-TEST CONT setting and elevation sheaf SMR code Starts menus target location target number TEST UNK Unknown WORDS CONT WPN AMMO WPN DATA