Operator's and Organizational Maintenance Manual (including Repair Parts and Special Tools List): Mortar Ballistics Computer Set, M23 (1220-01-119-6049).Headquarters, Department of the Army, 1985 |
No grāmatas satura
1.–5. rezultāts no 49.
2-6. lappuse
... ENTRY о MSN EOM COMPUTE XMIT Control or Indicator Key 22 keys Function Eleven keys used to enter alpha or numeric characters and minus sign . Alpha or numeric selection for combination keys is either automatic or menu - selectable ...
... ENTRY о MSN EOM COMPUTE XMIT Control or Indicator Key 22 keys Function Eleven keys used to enter alpha or numeric characters and minus sign . Alpha or numeric selection for combination keys is either automatic or menu - selectable ...
2-12. lappuse
... entry are • DEFAULT • ALPHA • NUMERIC • CORRECTION • DIRECTION • MULTIPLE CHOICE The following examples use only the SET UP switch menus to demonstrate each type of data entry listed above . These data entry examples do , however ...
... entry are • DEFAULT • ALPHA • NUMERIC • CORRECTION • DIRECTION • MULTIPLE CHOICE The following examples use only the SET UP switch menus to demonstrate each type of data entry listed above . These data entry examples do , however ...
2-14. lappuse
... NUMERIC ENTRY - Press SEQ switch . ( Fill in the underlined blanks . ) Use keyboard to enter numeric tar- get block number range , for example 0001 and 9999. Leading zeros must be entered . THI . DATA ENTRY ( CONT ) Press 0 key three ...
... NUMERIC ENTRY - Press SEQ switch . ( Fill in the underlined blanks . ) Use keyboard to enter numeric tar- get block number range , for example 0001 and 9999. Leading zeros must be entered . THI . DATA ENTRY ( CONT ) Press 0 key three ...
2-59. lappuse
... entry , change timeout to 60 . Timeout is used to set number of seconds ( 15 , 30 , 45 , or 60 ) the display stays ... numeric entry , enter target numbering block . Select from range 0 through 9999. Enter 0001 , 9999 . Press SEQ switch ...
... entry , change timeout to 60 . Timeout is used to set number of seconds ( 15 , 30 , 45 , or 60 ) the display stays ... numeric entry , enter target numbering block . Select from range 0 through 9999. Enter 0001 , 9999 . Press SEQ switch ...
2-60. lappuse
... entry , clear Easting field . Using numeric entry , enter mini- mum Easting coordinate . Enter 096 . Enter minimum Easting and North- ing coordinates at lower left corner of your area of operations . Press SEQ switch . Using correc ...
... entry , clear Easting field . Using numeric entry , enter mini- mum Easting coordinate . Enter 096 . Enter minimum Easting and North- ing coordinates at lower left corner of your area of operations . Press SEQ switch . Using correc ...
Bieži izmantoti vārdi un frāzes
ABBREVIATIONS AND WORDS ACTION altitude azimuth Ballistics base piece Check CKFR Column connector continuing the mission coordinates DATA ENTRY DATA switch Deflection and charge direction and numeric DISPLAY ABBREVIATIONS DISPLAY Press SEQ entered by computer equipment ERROR MESSAGE field wire final protective fire fire for effect Fire line violation FIRE LN VIOL Fire request FIRE ZONES Fuze setting Grid Fire Mission higher maintenance level INITIALIZATION CONT INPUT MISSIONS CONT known point KNPT KNPT/TGT LEGAL ENTRIES MANUAL INPUT MISSIONS manually entered meters MICR mils Mission and target multiple choice entry National Stock Number number entered numeric entry obtained before continuing operation PMCS Press COMPUTE switch Press SEQ switch Proper clearance radio registration point Repair safety fan Section SELF-TEST CONT setting and elevation sheaf SMR code Starts menus target location target number TEST UNK Unknown WORDS CONT WPN AMMO WPN DATA