Operator's and Organizational Maintenance Manual (including Repair Parts and Special Tools List): Mortar Ballistics Computer Set, M23 (1220-01-119-6049).Headquarters, Department of the Army, 1985 |
No grāmatas satura
1.–5. rezultāts no 48.
2-55. lappuse
... meters Azimuth of fire : 0800 Deferred deflection : 2800 Weapon No. 1 : Direction - 1600 Distance - - 035 Weapon No. 3 : Direction - 4800 Distance - - 028 Weapon No. 4 : Direction - 4800 Distance · · 040 AMMO DATA switch ( Ammunition ...
... meters Azimuth of fire : 0800 Deferred deflection : 2800 Weapon No. 1 : Direction - 1600 Distance - - 035 Weapon No. 3 : Direction - 4800 Distance - - 028 Weapon No. 4 : Direction - 4800 Distance · · 040 AMMO DATA switch ( Ammunition ...
2-63. lappuse
... meters . E : 04000 N # 47000 ALT : 0750 Press SEQ switch . Using numeric entry , enter base piece azimuth of fire and deferred deflection in mils . Enter azimuth 800 . Enter deflection 2800 . AZ10800 DER : 2800 28 Press SEQ switch ...
... meters . E : 04000 N # 47000 ALT : 0750 Press SEQ switch . Using numeric entry , enter base piece azimuth of fire and deferred deflection in mils . Enter azimuth 800 . Enter deflection 2800 . AZ10800 DER : 2800 28 Press SEQ switch ...
2-64. lappuse
... meters from base piece . Enter 1600 and 035 . Repeat step 28 and enter weapons 3 and 4 with the following sample data : Weapon No. 3 : Direction - 4800 mils Distance 028 meters Weapon No. 4 : Direction - 4800 mils Distance 040 meters ...
... meters from base piece . Enter 1600 and 035 . Repeat step 28 and enter weapons 3 and 4 with the following sample data : Weapon No. 3 : Direction - 4800 mils Distance 028 meters Weapon No. 4 : Direction - 4800 mils Distance 040 meters ...
2-77. lappuse
... switch . Using numeric entry , enter KNPT altitude in meters when known . Enter 0290 . 74 Press SEQ switch . E : 06640 N # 51350 READY ALT : 0290 INITIALIZATION ( CONT ) Repeat steps 70 and 74 and 2-77 TM 9-1220-246-12 & P.
... switch . Using numeric entry , enter KNPT altitude in meters when known . Enter 0290 . 74 Press SEQ switch . E : 06640 N # 51350 READY ALT : 0290 INITIALIZATION ( CONT ) Repeat steps 70 and 74 and 2-77 TM 9-1220-246-12 & P.
2-79. lappuse
... meters . Enter 0550 . DISPLAY 80 Press SEQ switch . Repeat steps 75 through 80 and enter target 15 using the KNPT / TGT data provided . READY REG DATA ALT : 0550 Use REG DATA switch to enter new registration data , to review existing ...
... meters . Enter 0550 . DISPLAY 80 Press SEQ switch . Repeat steps 75 through 80 and enter target 15 using the KNPT / TGT data provided . READY REG DATA ALT : 0550 Use REG DATA switch to enter new registration data , to review existing ...
Bieži izmantoti vārdi un frāzes
ABBREVIATIONS AND WORDS ACTION altitude azimuth Ballistics base piece Check CKFR Column connector continuing the mission coordinates DATA ENTRY DATA switch Deflection and charge direction and numeric DISPLAY ABBREVIATIONS DISPLAY Press SEQ entered by computer equipment ERROR MESSAGE field wire final protective fire fire for effect Fire line violation FIRE LN VIOL Fire request FIRE ZONES Fuze setting Grid Fire Mission higher maintenance level INITIALIZATION CONT INPUT MISSIONS CONT known point KNPT KNPT/TGT LEGAL ENTRIES MANUAL INPUT MISSIONS manually entered meters MICR mils Mission and target multiple choice entry National Stock Number number entered numeric entry obtained before continuing operation PMCS Press COMPUTE switch Press SEQ switch Proper clearance radio registration point Repair safety fan Section SELF-TEST CONT setting and elevation sheaf SMR code Starts menus target location target number TEST UNK Unknown WORDS CONT WPN AMMO WPN DATA