Operator's and Organizational Maintenance Manual (including Repair Parts and Special Tools List): Mortar Ballistics Computer Set, M23 (1220-01-119-6049).Headquarters, Department of the Army, 1985 |
No grāmatas satura
1.–5. rezultāts no 22.
2-2. lappuse
... base piece , and individual weapon locations . 3 FO LOC switch Starts menus for entry of forward observer ( FO ) data : FO number , location , and altitude . 4 REG DATA switch Starts menus for manually entering a registration data file ...
... base piece , and individual weapon locations . 3 FO LOC switch Starts menus for entry of forward observer ( FO ) data : FO number , location , and altitude . 4 REG DATA switch Starts menus for manually entering a registration data file ...
2-5. lappuse
... base piece location . Returns display to first line of a message or to main menu currently in use . CONTROLS AND INDICATORS ( CONT ) KEYS 22 7 8 2-5 TM 9-1220-246-12 & P.
... base piece location . Returns display to first line of a message or to main menu currently in use . CONTROLS AND INDICATORS ( CONT ) KEYS 22 7 8 2-5 TM 9-1220-246-12 & P.
2-55. lappuse
... Base piece : A2 Base piece location E : 04000 N : 47000 Altitude : 0750 meters Azimuth of fire : 0800 Deferred deflection : 2800 Weapon No. 1 : Direction - 1600 Distance - - 035 Weapon No. 3 : Direction - 4800 Distance - - 028 Weapon No ...
... Base piece : A2 Base piece location E : 04000 N : 47000 Altitude : 0750 meters Azimuth of fire : 0800 Deferred deflection : 2800 Weapon No. 1 : Direction - 1600 Distance - - 035 Weapon No. 3 : Direction - 4800 Distance - - 028 Weapon No ...
2-62. lappuse
... base piece ( A1 , B1 , C1 ) . The base piece weapon ( Easting and Northing coordinates ) is the reference point for identifying and adding additional weapons to a section . Press WPN DATA switch . Using multiple choice entry , select ...
... base piece ( A1 , B1 , C1 ) . The base piece weapon ( Easting and Northing coordinates ) is the reference point for identifying and adding additional weapons to a section . Press WPN DATA switch . Using multiple choice entry , select ...
2-63. lappuse
... base piece number . Enter 2 . 107 BP : A Press SEQ switch . Using numeric entry , enter base piece Easting and Northing map coordinates . Enter Easting 04000. Enter Northing 47000 . Press SEQ switch . Using numeric entry , enter altitude of ...
... base piece number . Enter 2 . 107 BP : A Press SEQ switch . Using numeric entry , enter base piece Easting and Northing map coordinates . Enter Easting 04000. Enter Northing 47000 . Press SEQ switch . Using numeric entry , enter altitude of ...
Bieži izmantoti vārdi un frāzes
ABBREVIATIONS AND WORDS ACTION altitude azimuth Ballistics base piece Check CKFR Column connector continuing the mission coordinates DATA ENTRY DATA switch Deflection and charge direction and numeric DISPLAY ABBREVIATIONS DISPLAY Press SEQ entered by computer equipment ERROR MESSAGE field wire final protective fire fire for effect Fire line violation FIRE LN VIOL Fire request FIRE ZONES Fuze setting Grid Fire Mission higher maintenance level INITIALIZATION CONT INPUT MISSIONS CONT known point KNPT KNPT/TGT LEGAL ENTRIES MANUAL INPUT MISSIONS manually entered meters MICR mils Mission and target multiple choice entry National Stock Number number entered numeric entry obtained before continuing operation PMCS Press COMPUTE switch Press SEQ switch Proper clearance radio registration point Repair safety fan Section SELF-TEST CONT setting and elevation sheaf SMR code Starts menus target location target number TEST UNK Unknown WORDS CONT WPN AMMO WPN DATA