Operator's and Organizational Maintenance Manual (including Repair Parts and Special Tools List): Mortar Ballistics Computer Set, M23 (1220-01-119-6049).Headquarters, Department of the Army, 1985 |
No grāmatas satura
1.–5. rezultāts no 28.
1-6. lappuse
... Fire Zones Final Protective Fire Lines Safety Min - Max Charge Zones Firing Section Solutions No Fire Line Points Per No Fire Area Quantity 3 33 3 18 12 50 16 3 10 33618 8 EQUIPMENT DATA ( CONT ) Radio Wire Bit Rate Block 1-6 TM 9-1220 ...
... Fire Zones Final Protective Fire Lines Safety Min - Max Charge Zones Firing Section Solutions No Fire Line Points Per No Fire Area Quantity 3 33 3 18 12 50 16 3 10 33618 8 EQUIPMENT DATA ( CONT ) Radio Wire Bit Rate Block 1-6 TM 9-1220 ...
2-1. lappuse
... FIRE ZONES STANDBY INDICATOR MIOR SO DOP MOD 0 0 0 0 7 STU vwx Y2 DISPLAY DISPLAY SWITCHES- INTERACT WITH DISPLAY SEQUENCE INDICATOR BATT LOW INDICATOR ACTION SWITCHES- DATA ENTRY , COMPUTATION , JKL MNO REVIEW AND END RE- BACK FIRE ...
... FIRE ZONES STANDBY INDICATOR MIOR SO DOP MOD 0 0 0 0 7 STU vwx Y2 DISPLAY DISPLAY SWITCHES- INTERACT WITH DISPLAY SEQUENCE INDICATOR BATT LOW INDICATOR ACTION SWITCHES- DATA ENTRY , COMPUTATION , JKL MNO REVIEW AND END RE- BACK FIRE ...
2-2. lappuse
... FIRE ZONES Control or Key Indicator Function 10 9 8 7 1 SET UP switch 2 WPN DATA switch Starts menus for entry of setup data : timeout , target pre- fix and block number range , location grid declination , message transmission rate ...
... FIRE ZONES Control or Key Indicator Function 10 9 8 7 1 SET UP switch 2 WPN DATA switch Starts menus for entry of setup data : timeout , target pre- fix and block number range , location grid declination , message transmission rate ...
2-3. lappuse
... FIRE ZONES switch 8 MET switch Function Selects level of brightness for display area . keyboard background lighting ... fire zone boundaries / fire lines ( fire areas ) : location points for fire lines ; zone number , number of points ...
... FIRE ZONES switch 8 MET switch Function Selects level of brightness for display area . keyboard background lighting ... fire zone boundaries / fire lines ( fire areas ) : location points for fire lines ; zone number , number of points ...
2-10. lappuse
... FIRE ON ZONES OFF MIOR SU DEP DOP MOD 38 0 0 39 7 8 STU vwx YZ Msa SEQ 4 5 JKL MNO POR RE- BACK VIEW 1 2 3 ABC DEF CHI BATT SURV LOW 40 CLEAR ENTRY CONTROLS AND INDICATORS ( CONT ) Control or Key Indicator 2-10 TM 9-1220-246-12 & P.
... FIRE ON ZONES OFF MIOR SU DEP DOP MOD 38 0 0 39 7 8 STU vwx YZ Msa SEQ 4 5 JKL MNO POR RE- BACK VIEW 1 2 3 ABC DEF CHI BATT SURV LOW 40 CLEAR ENTRY CONTROLS AND INDICATORS ( CONT ) Control or Key Indicator 2-10 TM 9-1220-246-12 & P.
Bieži izmantoti vārdi un frāzes
ABBREVIATIONS AND WORDS ACTION altitude azimuth Ballistics base piece Check CKFR Column connector continuing the mission coordinates DATA ENTRY DATA switch Deflection and charge direction and numeric DISPLAY ABBREVIATIONS DISPLAY Press SEQ entered by computer equipment ERROR MESSAGE field wire final protective fire fire for effect Fire line violation FIRE LN VIOL Fire request FIRE ZONES Fuze setting Grid Fire Mission higher maintenance level INITIALIZATION CONT INPUT MISSIONS CONT known point KNPT KNPT/TGT LEGAL ENTRIES MANUAL INPUT MISSIONS manually entered meters MICR mils Mission and target multiple choice entry National Stock Number number entered numeric entry obtained before continuing operation PMCS Press COMPUTE switch Press SEQ switch Proper clearance radio registration point Repair safety fan Section SELF-TEST CONT setting and elevation sheaf SMR code Starts menus target location target number TEST UNK Unknown WORDS CONT WPN AMMO WPN DATA