... 1-3 . HOW TO TROUBLESHOOT ( CONT ) A DO INSPECTION UPON RECEIPT ( VOL II , CHAP 3 ) . LIST EVERY FAULT YOU SEE ON DA FORM 2404 ( JPG 41C ) . TM 9-1220-220-34 CORRECT ALL FAULTS LISTED BON DA FORM 2404 ... FRAME 2 Step Procedure 1 . 2 . Vol I.
... 1-3 . HOW TO TROUBLESHOOT ( CONT ) A DO INSPECTION UPON RECEIPT ( VOL II , CHAP 3 ) . LIST EVERY FAULT YOU SEE ON DA FORM 2404 ( JPG 41C ) . TM 9-1220-220-34 CORRECT ALL FAULTS LISTED BON DA FORM 2404 ... FRAME 2 Step Procedure 1 . 2 . Vol I.
2-2. lappuse
... FRAME 1 Step Procedure 1 . Set COMPUTER SWITCH ( 1 ) on range finder ( 2 ) to OFF . 2 . Pull out and turn range correction knob ( 3 ) on ballistics computer ( 4 ) until scale ( 5 ) reads 0 ( zero ) . 3. While looking into range scale ...
... FRAME 1 Step Procedure 1 . Set COMPUTER SWITCH ( 1 ) on range finder ( 2 ) to OFF . 2 . Pull out and turn range correction knob ( 3 ) on ballistics computer ( 4 ) until scale ( 5 ) reads 0 ( zero ) . 3. While looking into range scale ...
2-4. lappuse
... Step Procedure 1 . 2 . 3 . 4 . 5 . Set range correction knob ( 1 ) on ballistics computer ( 2 ) according to the ... frame 4 , and para 4-5 , frame 9 ) . GO TO FRAME 3 Para 2-2 Cont Vol I 2-2 . FRAME 3 Step Procedure 1 . Check that 2-4 ...
... Step Procedure 1 . 2 . 3 . 4 . 5 . Set range correction knob ( 1 ) on ballistics computer ( 2 ) according to the ... frame 4 , and para 4-5 , frame 9 ) . GO TO FRAME 3 Para 2-2 Cont Vol I 2-2 . FRAME 3 Step Procedure 1 . Check that 2-4 ...
2-6. lappuse
... FRAME 3 Step Procedure 1 . Check that ballistic computer ( 1 ) does not move back and forth more than ten times or does not stall . 2 . Set circuit breaker switch ( 2 ) to OFF . 3 . Symptom Maintenance Action Oscillation or stalling in ...
... FRAME 3 Step Procedure 1 . Check that ballistic computer ( 1 ) does not move back and forth more than ten times or does not stall . 2 . Set circuit breaker switch ( 2 ) to OFF . 3 . Symptom Maintenance Action Oscillation or stalling in ...
2-8. lappuse
... FRAME 4 Step Procedure 1 . 2 . Set circuit breaker switch ( 1 ) to OFF . While looking into range view housing window ( 2 ) of Symptom Maintenance Action range finder ( 3 ) , turn range knob ( 4 ) until range scale reads 500 meters . 3 ...
... FRAME 4 Step Procedure 1 . 2 . Set circuit breaker switch ( 1 ) to OFF . While looking into range view housing window ( 2 ) of Symptom Maintenance Action range finder ( 3 ) , turn range knob ( 4 ) until range scale reads 500 meters . 3 ...
Bieži izmantoti vārdi un frāzes
050 allen wrench 3/16 pin spanner BALLISTICS DRIVE INSPECTION BALLISTICS DRIVE INSTALLATION BALLISTICS DRIVE REMOVAL box end wrench capscrew circuit breaker switch cotter pin DRIVE CONNECTOR DRIVE INSTALLATION CONT DRIVE REMOVAL CONT elevation quadrant END OF TASK EQUIPMENT CONDITION fire control level flat tip screwdriver flat washer foot-pounds four lockwashers FRAME 1 Step GO TO FRAME gunner's periscope holding cap hose clamp INSPECTION UPON RECEIPT JPG 41C junction box assembly LEVEL VIAL LIGHT ASSEMBLY link connector assembly lockwire M10 Series Ballistics NOTE FOLLOW-ON MAINTENANCE number of turns open end wrench Para 4-5 Cont Para Para PERFORMANCE TEST CONT performance test Vol pin spanner wrench range finder rangefinder link connector RECEIPT CONT remove four screws Repairman Replace if missing Series Ballistics Drive Set circuit breaker SHAFT AND RELATED SIDE OF CONNECTING Step BALLISTICS DRIVE Step Procedure SUPERELEVATION BOX ASSEMBLY temperature compensating rod torque wrench trunnion link turret mounting pad universal joint