Direct Support and General Support Maintenance Manual: Ballistic Drive, M10 (1220-00-676-2184), M10A1 (1220-00-076-9765), M10A3 (1220-00-572-8735), M10A4 (1220-00-856-9453), M10A5 (1220-00-980-9297), M10A6 (1220-00-933-1203).Headquarters, Department of the Army, 1985 |
No grāmatas satura
1.–5. rezultāts no 21.
11. lappuse
... checking out the M10 Series Ballistics Drive and for finding fault symptoms are given in Chapter 2. See paragraph 1-3 for how to troubleshoot . Para 1-1 1-1 TM 9-1220-220-34 1-3 . HOW TO TROUBLESHOOT The following steps Vol I.
... checking out the M10 Series Ballistics Drive and for finding fault symptoms are given in Chapter 2. See paragraph 1-3 for how to troubleshoot . Para 1-1 1-1 TM 9-1220-220-34 1-3 . HOW TO TROUBLESHOOT The following steps Vol I.
12. lappuse
... check and list any faults on DA Form 2404 before making repairs . See Vol II , Chap 3 for what to check for . If you see any faults that may affect the performance test , fix them now . This does not mean small things like painting ...
... check and list any faults on DA Form 2404 before making repairs . See Vol II , Chap 3 for what to check for . If you see any faults that may affect the performance test , fix them now . This does not mean small things like painting ...
13. lappuse
... CHECK FAULT SYMPTOM INDEX ( VOL I , CHAP 3 ) AND DO DO MAINTENANCE ( VOL II , CHAP 4 ) OR FAULT ISOLATION ( VOL I , CHAP 4 ) TO CORRECT FAULT SYMPTOM . DO PERFORMANCE TEST ( VOLI , CHAP 2 ) UNTIL A FAULT SYMPTOM IS FOUND D ) REPEAT ...
... CHECK FAULT SYMPTOM INDEX ( VOL I , CHAP 3 ) AND DO DO MAINTENANCE ( VOL II , CHAP 4 ) OR FAULT ISOLATION ( VOL I , CHAP 4 ) TO CORRECT FAULT SYMPTOM . DO PERFORMANCE TEST ( VOLI , CHAP 2 ) UNTIL A FAULT SYMPTOM IS FOUND D ) REPEAT ...
2-2. lappuse
... Check that inner ( range ) pointer ( 8 ) of ballistics computer ( 4 ) reads 1000 meters . Set driver's master control panel ( 9 ) MASTER SWITCH ( 10 ) to ON . 6 . Set COMPUTER switch ( 1 ) on range finder ( 2 ) to ON . GO TO FRAME 2 ...
... Check that inner ( range ) pointer ( 8 ) of ballistics computer ( 4 ) reads 1000 meters . Set driver's master control panel ( 9 ) MASTER SWITCH ( 10 ) to ON . 6 . Set COMPUTER switch ( 1 ) on range finder ( 2 ) to ON . GO TO FRAME 2 ...
2-4. lappuse
... Check that range movement ( reading of outer pointer ( 8 ) ) is the same as reading on inner pointer ( 9 ) . Range movement is not the same Set circuit breaker switch to OFF . Place correct number of turns on input shaft Vol II , para 4 ...
... Check that range movement ( reading of outer pointer ( 8 ) ) is the same as reading on inner pointer ( 9 ) . Range movement is not the same Set circuit breaker switch to OFF . Place correct number of turns on input shaft Vol II , para 4 ...
Bieži izmantoti vārdi un frāzes
050 allen wrench 3/16 pin spanner BALLISTICS DRIVE INSPECTION BALLISTICS DRIVE INSTALLATION BALLISTICS DRIVE REMOVAL box end wrench capscrew circuit breaker switch cotter pin DRIVE CONNECTOR DRIVE INSTALLATION CONT DRIVE REMOVAL CONT elevation quadrant END OF TASK EQUIPMENT CONDITION fire control level flat tip screwdriver flat washer foot-pounds four lockwashers FRAME 1 Step GO TO FRAME gunner's periscope holding cap hose clamp INSPECTION UPON RECEIPT JPG 41C junction box assembly LEVEL VIAL LIGHT ASSEMBLY link connector assembly lockwire M10 Series Ballistics NOTE FOLLOW-ON MAINTENANCE number of turns open end wrench Para 4-5 Cont Para Para PERFORMANCE TEST CONT performance test Vol pin spanner wrench range finder rangefinder link connector RECEIPT CONT remove four screws Repairman Replace if missing Series Ballistics Drive Set circuit breaker SHAFT AND RELATED SIDE OF CONNECTING Step BALLISTICS DRIVE Step Procedure SUPERELEVATION BOX ASSEMBLY temperature compensating rod torque wrench trunnion link turret mounting pad universal joint