Operator's Manual for Multiple Integrated Laser Engagement System (MILES), Simulator System, Firing, Laser: M82, M1 Abrams Tank, NSN 1265-01-137-7697Headquarters, Department of the Army, 1983 |
No grāmatas satura
1.–5. rezultāts no 9.
1-12. lappuse
... boresight the equipment . To operate M240 and M2 machine gun transmitters in dry fire mode a controller key must be used to set the transmitter . A dry fire trigger cable is used to fire those transmitters . A dry fire plug is used for ...
... boresight the equipment . To operate M240 and M2 machine gun transmitters in dry fire mode a controller key must be used to set the transmitter . A dry fire trigger cable is used to fire those transmitters . A dry fire plug is used for ...
2-69. lappuse
... boresight target prior to starting this task . The recommended boresight range is 1200 meters . • Make sure TURRET POWER is ON . 1. Open COMPUTER CONTROL PANEL ( CCP ) door and set POWER switch ( 1 ) to ON . 2 . 3 . 4 . 5 . Make sure ...
... boresight target prior to starting this task . The recommended boresight range is 1200 meters . • Make sure TURRET POWER is ON . 1. Open COMPUTER CONTROL PANEL ( CCP ) door and set POWER switch ( 1 ) to ON . 2 . 3 . 4 . 5 . Make sure ...
2-72. lappuse
... boresight target using manual turret and elevation crank handles . Recommended boresight range is 1200 meters . 31. Verify that LEAD ( 13 ) , CANT ( 15 ) , CROSSWIND ( 16 ) , and RANGE ( 19 ) keys are lit. If not , repeat steps 7 8 9 5 ...
... boresight target using manual turret and elevation crank handles . Recommended boresight range is 1200 meters . 31. Verify that LEAD ( 13 ) , CANT ( 15 ) , CROSSWIND ( 16 ) , and RANGE ( 19 ) keys are lit. If not , repeat steps 7 8 9 5 ...
2-73. lappuse
... boresight target . 34. When reticle is aligned on boresight target , press ENTER key ( 11 ) . 35. Press ZERO key ( 12 ) . 36. While looking through the Gunner's Primary Sight ( GPS ) , move TOGGLE switch ( 10 ) up ( U ) , down ( D ) ...
... boresight target . 34. When reticle is aligned on boresight target , press ENTER key ( 11 ) . 35. Press ZERO key ( 12 ) . 36. While looking through the Gunner's Primary Sight ( GPS ) , move TOGGLE switch ( 10 ) up ( U ) , down ( D ) ...
2-74. lappuse
... boresight target prior to starting this task . The recommended boresight range is 1200 meters . Make sure vehicle power is on . 1. Open COMPUTER CONTROL PANEL ( CCP ) door and set POWER switch ( 1 ) to ON . 2. Make sure PWR indicator ...
... boresight target prior to starting this task . The recommended boresight range is 1200 meters . Make sure vehicle power is on . 1. Open COMPUTER CONTROL PANEL ( CCP ) door and set POWER switch ( 1 ) to ON . 2. Make sure PWR indicator ...
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
alarm Align Subtask Ask controller attached battery box blank ammunition blank fire blank fire adapter Blank Fire Attachment boresight target breech BUSINESS REPLY MAIL bustle rack cable labeled coax machine gun COMPONENTS OF END connector Cont control console controller key CVKI Cable Assembly CVKI light detector belt segments display window dry fire END ITEM ENTER key 11 fastener tape Fluid Ounces Helmet Harness Hoffman device Inches Inside Subtask Inside Task Inspect and Service intercom loader's hatch M1 Abrams Tank M1 Tank M2 Machine Gun M2 MG M240 machine M240 MG Task machine gun transmitter main gun Meters MG Laser Transmitter MG Transmitter microphone MILES cables MILES equipment MILES system mm/Coax mounting MWLD Task National Stock Number opposing fire Postoperational and Storage Postoperational Tasks Press ENTER key prevent normal operation receptacle reloading Report any damage Simulator System Storage Task Subtask 1-A Test Subtask torso harness Troubleshooting turn turret window 9