Operator's Manual for Multiple Integrated Laser Engagement System (MILES), Simulator System, Firing, Laser: M82, M1 Abrams Tank, NSN 1265-01-137-7697Headquarters, Department of the Army, 1983 |
No grāmatas satura
1.–5. rezultāts no 19.
1-5. lappuse
... alarm sounds , it is put in the MWLD key receptacle to silence alarm . EQUIPMENT DATA Laser Transmitters Table 1-1 . MILES M1 Tank 1.5 TM 9-1265-373-10-1.
... alarm sounds , it is put in the MWLD key receptacle to silence alarm . EQUIPMENT DATA Laser Transmitters Table 1-1 . MILES M1 Tank 1.5 TM 9-1265-373-10-1.
1-9. lappuse
... alarms . Provides electrical signals to fire main gun / coax machine gun transmitter . Contains a key receptacle for initializing system , silencing intercom alarm and resetting system . Mounts on left side of turret on tank support ...
... alarms . Provides electrical signals to fire main gun / coax machine gun transmitter . Contains a key receptacle for initializing system , silencing intercom alarm and resetting system . Mounts on left side of turret on tank support ...
1-11. lappuse
... alarms indicating the presence and damage of opposing fire . The MILES system of laser beam transmitters and detectors ... alarm on the torso harness is set off . MAIN GUN MILES FIRING The main gun is fired using normal procedures . A ...
... alarms indicating the presence and damage of opposing fire . The MILES system of laser beam transmitters and detectors ... alarm on the torso harness is set off . MAIN GUN MILES FIRING The main gun is fired using normal procedures . A ...
1-13. lappuse
... alarm on the harness sounds briefly . This means a " NEAR MISS " occurred . It is a warning to take cover . 2 . The alarm sounds continuously . This means the soldier has been " KILLED " . He must use a yellow key to turn off the alarm ...
... alarm on the harness sounds briefly . This means a " NEAR MISS " occurred . It is a warning to take cover . 2 . The alarm sounds continuously . This means the soldier has been " KILLED " . He must use a yellow key to turn off the alarm ...
2-1. lappuse
... alarm alarm . Turn controller key to CONTROLLER to reset . PRESS TO READ Pushbutton Switch Activates display Press to activate display 5 NOT READY Light Emitting Lights when N / A 6 Diode ( LED ) not ready , " killed , " or for 5 ...
... alarm alarm . Turn controller key to CONTROLLER to reset . PRESS TO READ Pushbutton Switch Activates display Press to activate display 5 NOT READY Light Emitting Lights when N / A 6 Diode ( LED ) not ready , " killed , " or for 5 ...
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
alarm Align Subtask Ask controller attached battery box blank ammunition blank fire blank fire adapter Blank Fire Attachment boresight target breech BUSINESS REPLY MAIL bustle rack cable labeled coax machine gun COMPONENTS OF END connector Cont control console controller key CVKI Cable Assembly CVKI light detector belt segments display window dry fire END ITEM ENTER key 11 fastener tape Fluid Ounces Helmet Harness Hoffman device Inches Inside Subtask Inside Task Inspect and Service intercom loader's hatch M1 Abrams Tank M1 Tank M2 Machine Gun M2 MG M240 machine M240 MG Task machine gun transmitter main gun Meters MG Laser Transmitter MG Transmitter microphone MILES cables MILES equipment MILES system mm/Coax mounting MWLD Task National Stock Number opposing fire Postoperational and Storage Postoperational Tasks Press ENTER key prevent normal operation receptacle reloading Report any damage Simulator System Storage Task Subtask 1-A Test Subtask torso harness Troubleshooting turn turret window 9