Operator's Manual for Multiple Integrated Laser Engagement System (MILES), Simulator System, Firing, Laser: M82, M1 Abrams Tank, NSN 1265-01-137-7697Headquarters, Department of the Army, 1983 |
No grāmatas satura
1.–5. rezultāts no 6.
2-36. lappuse
... Subtask 9B . If your gun is equipped with a 105 mm main gun go to Subtask 9A . Inside Subtask 9A : Install 105 mm ... TEST tasks to check its operation . Inside Subtask 9B : Install 120 mm / Coax MG 2.36 TM 9-1265-373-10-1.
... Subtask 9B . If your gun is equipped with a 105 mm main gun go to Subtask 9A . Inside Subtask 9A : Install 105 mm ... TEST tasks to check its operation . Inside Subtask 9B : Install 120 mm / Coax MG 2.36 TM 9-1265-373-10-1.
2-43. lappuse
Inside Subtask 13 - B : Install Trigger Cable Assembly . 1- 4 3 2_ Locate the MILES cable labeled TRIGGER . Connect ... TEST 1 to TEST 1 receptacle ( 3 ) . NOTE There is one plug remaining on the cable labeled P3 HOFFMAN TRIGGER . If no ...
Inside Subtask 13 - B : Install Trigger Cable Assembly . 1- 4 3 2_ Locate the MILES cable labeled TRIGGER . Connect ... TEST 1 to TEST 1 receptacle ( 3 ) . NOTE There is one plug remaining on the cable labeled P3 HOFFMAN TRIGGER . If no ...
2-64. lappuse
Test Task 2 : Test MILES System . Testing of MILES system consists of the following subtasks : Test Subtask 2 - A : Control Console Test Test Subtask 2 - B : Trigger Interface Test Test Subtask 2 - C : Main Gun Transmitter Test Test ...
Test Task 2 : Test MILES System . Testing of MILES system consists of the following subtasks : Test Subtask 2 - A : Control Console Test Test Subtask 2 - B : Trigger Interface Test Test Subtask 2 - C : Main Gun Transmitter Test Test ...
2-65. lappuse
Test Subtask 2 - A : Control Console Test ( Cont ) . Insert orange weapon key ( 10 ) into control console receptacle ( 11 ) . Turn key , then turn key back and remove . Verify that a tone sounds in the vehicle intercom , the CVKI light ...
Test Subtask 2 - A : Control Console Test ( Cont ) . Insert orange weapon key ( 10 ) into control console receptacle ( 11 ) . Turn key , then turn key back and remove . Verify that a tone sounds in the vehicle intercom , the CVKI light ...
2-66. lappuse
Test Subtask 2 - D : Coax Machine Gun Transmitter Test . Make sure coax machine gun is loaded with blank ammunition ... Test Subtask 2 - E : Belt Test . 77 2-66 TM 9-1265-373-10-1.
Test Subtask 2 - D : Coax Machine Gun Transmitter Test . Make sure coax machine gun is loaded with blank ammunition ... Test Subtask 2 - E : Belt Test . 77 2-66 TM 9-1265-373-10-1.
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
alarm Align Subtask Ask controller attached battery box blank ammunition blank fire blank fire adapter Blank Fire Attachment boresight target breech BUSINESS REPLY MAIL bustle rack cable labeled coax machine gun COMPONENTS OF END connector Cont control console controller key CVKI Cable Assembly CVKI light detector belt segments display window dry fire END ITEM ENTER key 11 fastener tape Fluid Ounces Helmet Harness Hoffman device Inches Inside Subtask Inside Task Inspect and Service intercom loader's hatch M1 Abrams Tank M1 Tank M2 Machine Gun M2 MG M240 machine M240 MG Task machine gun transmitter main gun Meters MG Laser Transmitter MG Transmitter microphone MILES cables MILES equipment MILES system mm/Coax mounting MWLD Task National Stock Number opposing fire Postoperational and Storage Postoperational Tasks Press ENTER key prevent normal operation receptacle reloading Report any damage Simulator System Storage Task Subtask 1-A Test Subtask torso harness Troubleshooting turn turret window 9