Log Data Acquisition and...Editions OPHRYS, 1991 - 330 lappuses |
No grāmatas satura
1.–5. rezultāts no 30.
14. lappuse
... operating company . Therefore , in principle , it could be possible to investigate the formation at any dis- tance , if the well test duration is sufficiently long . In practice , however , two additional parameters come into play , the ...
... operating company . Therefore , in principle , it could be possible to investigate the formation at any dis- tance , if the well test duration is sufficiently long . In practice , however , two additional parameters come into play , the ...
35. lappuse
... operating practice has been followed and is indispensable in the process of removing blunders . This is reviewed in Chapter 21 . Once the blunders are totally eradicated , any error can be viewed as the super- position of systematic and ...
... operating practice has been followed and is indispensable in the process of removing blunders . This is reviewed in Chapter 21 . Once the blunders are totally eradicated , any error can be viewed as the super- position of systematic and ...
36. lappuse
... operating mode , radioactive sources are not removed from the calibration area and this parasitic signal introduces a systematic error in the measurement . ( d ) Ensure that the logging procedures have been well defined and are ...
... operating mode , radioactive sources are not removed from the calibration area and this parasitic signal introduces a systematic error in the measurement . ( d ) Ensure that the logging procedures have been well defined and are ...
37. lappuse
... operating procedures have not changed , the systematic error can be removed from previous measurements . Example 1 The response of a density tool has been established with an artificial limestone block improperly characterized by a ...
... operating procedures have not changed , the systematic error can be removed from previous measurements . Example 1 The response of a density tool has been established with an artificial limestone block improperly characterized by a ...
43. lappuse
... operating procedures 4. stable behavior of the downhole equipment under high pressure and temperature 5. tight control of the environment . Figure 4.4 represents accuracy and precision for a true value X and two measure- ments 1 and 2 ...
... operating procedures 4. stable behavior of the downhole equipment under high pressure and temperature 5. tight control of the environment . Figure 4.4 represents accuracy and precision for a true value X and two measure- ments 1 and 2 ...
Saturs
LXXXII | 220 |
LXXXIII | 227 |
LXXXV | 228 |
LXXXVI | 233 |
LXXXVIII | 234 |
LXXXIX | 236 |
XC | 238 |
XCI | 242 |
23 | |
24 | |
25 | |
28 | |
33 | |
36 | |
37 | |
42 | |
45 | |
46 | |
47 | |
48 | |
56 | |
61 | |
XXVIII | 69 |
XXIX | 71 |
XXX | 73 |
XXXI | 75 |
XXXII | 76 |
XXXIV | 77 |
XXXV | 79 |
XXXVII | 81 |
XXXVIII | 83 |
XXXIX | 87 |
XL | 90 |
XLI | 95 |
XLII | 99 |
XLIII | 101 |
XLIV | 103 |
XLV | 107 |
XLVI | 109 |
XLVII | 113 |
XLVIII | 117 |
XLIX | 120 |
L | 124 |
LI | 130 |
LII | 133 |
LIII | 134 |
LIV | 135 |
LV | 139 |
LVI | 140 |
LVII | 142 |
LVIII | 144 |
LIX | 147 |
LXII | 151 |
LXIII | 153 |
LXIV | 159 |
LXV | 160 |
LXVI | 161 |
LXVII | 164 |
LXVIII | 167 |
LXIX | 175 |
LXX | 176 |
LXXI | 177 |
LXXII | 180 |
LXXIII | 186 |
LXXIV | 190 |
LXXV | 191 |
LXXVI | 192 |
LXXVII | 199 |
LXXVIII | 203 |
LXXIX | 211 |
LXXX | 212 |
LXXXI | 217 |
XCII | 248 |
XCIII | 259 |
XCIV | 262 |
XCV | 269 |
XCVI | 273 |
XCVII | 274 |
XCVIII | 275 |
XCIX | 277 |
C | 286 |
CI | 292 |
CII | 293 |
CIII | 294 |
CIV | 297 |
CV | 299 |
CVI | 301 |
CVII | 304 |
CVIII | 307 |
CIX | 309 |
CX | 310 |
CXI | 314 |
CXII | 321 |
CXIII | 325 |
CXIV | 326 |
CXV | 330 |
CXVI | 331 |
CXVIII | 333 |
CXIX | 334 |
CXX | 337 |
CXXI | 339 |
CXXII | 340 |
CXXIII | 343 |
CXXIV | 344 |
CXXV | 346 |
CXXVI | 348 |
CXXVII | 349 |
CXXVIII | 353 |
CXXX | 359 |
CXXXI | 361 |
CXXXII | 362 |
CXXXIII | 364 |
CXXXIV | 373 |
CXXXV | 374 |
CXXXVI | 375 |
CXXXVII | 376 |
CXXXVIII | 380 |
CXXXIX | 385 |
CXL | 386 |
CXLI | 394 |
CXLII | 395 |
CXLIII | 398 |
CXLIV | 407 |
CXLV | 413 |
CXLVII | 416 |
CXLVIII | 420 |
CXLIX | 423 |
CL | 428 |
CLII | 431 |
CLIII | 433 |
CLIV | 437 |
CLV | 439 |
CLVI | 447 |
CLVII | 449 |
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
accuracy acquisition Anadrill analysis annual logging symposium axis barite borehole cable calibration caliper characteristics computed core corresponds counting rates Courtesy of Schlumberger Courtesy of SPWLA curves data quality defined density logging depth matching depth of investigation derived detector device diameter downhole drilling effect environment environmental corrections example filtering fluid formation evaluation ft/h g/cm³ gamma ray geometrical factor Halliburton Logging Services hole input interval invasion laterolog Log Analyst log quality control logging company logging data logging speed logging tool measurement METER method mmho/m modeling mudcake neutron porosity nonconformities ohm-m oil-base mud parameters performed petrophysical precision pressure reference reservoir resistivity sampling rate seismic sensors signal sonde error sonic standard deviation standoff surface systematic error TABLE temperature thermal neutron tool response Trans uncertainty vertical resolution volume water saturation wellsite wireline logging zone
Populāri fragmenti
233. lappuse - RM is defined as a material or substance one or more properties of which are sufficiently well established to be used for the calibration of an apparatus, the assessment of a measurement method, or for assigning values to materials.
46. lappuse - Parameter, associated with the result of a measurement, that characterizes the dispersion of the values that could reasonably be attributed to the measurand.
434. lappuse - ... for practical purposes, the value towards which the average of single results obtained by N laboratories tends, when N becomes very large (Note 5). Consequently, such a true value is associated with the particular method of test employed.
233. lappuse - Set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system, or values represented by a material measure or a reference material, and the corresponding values realized by standards.
233. lappuse - The set of operations which establish, under specified conditions, the relationship between values indicated by a measuring instrument or measuring system, or values represented by a material measure, and the corresponding known values of a reference standard.
343. lappuse - I have made this letter longer than usual, only because I have not had the time to make it shorter.
26. lappuse - ... Planning and Statement of Objectives USEPA has spent considerable effort in developing planning guidance, known as Data Quality Objectives (DQO's) which can be applicable to site assessment planning.(USEPA "Guidance for Data Quality Objective Process," QA/G-4(USEPA, 2000c). This process includes seven steps. - State the problem -Identify the decision -Identify inputs to the decision -Define study boundary areas -Develop a decision rule -Specify decision error limits -Optimize design for obtaining...
107. lappuse - The becquerel is the activity of a radionuclide decaying at the rate of one spontaneous nuclear transition per second. The degree Celsius is equal to the kelvin and is used in place of the kelvin for expressing Celsius temperature (symbol t) defined by the equation / = T - T0 where T is the thermodynamic temperature and T0 = 273.15 K.
Atsauces uz šo grāmatu
Statistical Regression Line-Fitting in the Oil and Gas Industry Richard Woodhouse Priekšskatījums nav pieejams - 2003 |