Log Data Acquisition and...Editions OPHRYS, 1991 - 330 lappuses |
No grāmatas satura
1.5. rezultāts no 41.
15. lappuse
... computed as ข t Fresnel radius = 4 F in which v is the average velocity to the reflector , t is the two - way time and ƒ is the center of the frequency content of the reflection . Numerical application At a depth of 3000 m ( 10,000 ft ) ...
... computed as ข t Fresnel radius = 4 F in which v is the average velocity to the reflector , t is the two - way time and ƒ is the center of the frequency content of the reflection . Numerical application At a depth of 3000 m ( 10,000 ft ) ...
28. lappuse
... calculated with the standard reservoir parameters . Develop a decision rule : When well productivity exceeds 30 b / d / psi , then the well angle is dropped ... computed from measured depth and 28 3. Data collection and decision - making XVI.
... calculated with the standard reservoir parameters . Develop a decision rule : When well productivity exceeds 30 b / d / psi , then the well angle is dropped ... computed from measured depth and 28 3. Data collection and decision - making XVI.
29. lappuse
Philippe P. Theys. ⚫ the true vertical depth computed from measured depth and a directional survey the formation pressures . The data is plotted ( Fig . 3.1 ) so that fluid ( oil , water or gas ) contacts are easily identified . Depth ...
Philippe P. Theys. ⚫ the true vertical depth computed from measured depth and a directional survey the formation pressures . The data is plotted ( Fig . 3.1 ) so that fluid ( oil , water or gas ) contacts are easily identified . Depth ...
41. lappuse
... than 2. In practice , only Σ ] is computed . 5Solutions to the exercises marked with an asterisk are found in Appendix 4 . TABLE 4.2 RELATION BETWEEN CONFIDENCE LEVEL AND LENGTH OF THE 4. Elements of metrology I : error analysis 41.
... than 2. In practice , only Σ ] is computed . 5Solutions to the exercises marked with an asterisk are found in Appendix 4 . TABLE 4.2 RELATION BETWEEN CONFIDENCE LEVEL AND LENGTH OF THE 4. Elements of metrology I : error analysis 41.
49. lappuse
... formula for Sw = = = = 2 and 30 pu , compute 5 su and Sw = 7.5 su . 2. Using the information in Table 5.1 , with Rm = 0.1 N / m , Rmf 0.1 / m , Sro 74.5 su , compute the corrections to the medium and deep induction and shallow focused ...
... formula for Sw = = = = 2 and 30 pu , compute 5 su and Sw = 7.5 su . 2. Using the information in Table 5.1 , with Rm = 0.1 N / m , Rmf 0.1 / m , Sro 74.5 su , compute the corrections to the medium and deep induction and shallow focused ...
Saturs
LXXXII | 220 |
LXXXIII | 227 |
LXXXV | 228 |
LXXXVI | 233 |
LXXXVIII | 234 |
LXXXIX | 236 |
XC | 238 |
XCI | 242 |
23 | |
24 | |
25 | |
28 | |
33 | |
36 | |
37 | |
42 | |
45 | |
46 | |
47 | |
48 | |
56 | |
61 | |
XXVIII | 69 |
XXIX | 71 |
XXX | 73 |
XXXI | 75 |
XXXII | 76 |
XXXIV | 77 |
XXXV | 79 |
XXXVII | 81 |
XXXVIII | 83 |
XXXIX | 87 |
XL | 90 |
XLI | 95 |
XLII | 99 |
XLIII | 101 |
XLIV | 103 |
XLV | 107 |
XLVI | 109 |
XLVII | 113 |
XLVIII | 117 |
XLIX | 120 |
L | 124 |
LI | 130 |
LII | 133 |
LIII | 134 |
LIV | 135 |
LV | 139 |
LVI | 140 |
LVII | 142 |
LVIII | 144 |
LIX | 147 |
LXII | 151 |
LXIII | 153 |
LXIV | 159 |
LXV | 160 |
LXVI | 161 |
LXVII | 164 |
LXVIII | 167 |
LXIX | 175 |
LXX | 176 |
LXXI | 177 |
LXXII | 180 |
LXXIII | 186 |
LXXIV | 190 |
LXXV | 191 |
LXXVI | 192 |
LXXVII | 199 |
LXXVIII | 203 |
LXXIX | 211 |
LXXX | 212 |
LXXXI | 217 |
XCII | 248 |
XCIII | 259 |
XCIV | 262 |
XCV | 269 |
XCVI | 273 |
XCVII | 274 |
XCVIII | 275 |
XCIX | 277 |
C | 286 |
CI | 292 |
CII | 293 |
CIII | 294 |
CIV | 297 |
CV | 299 |
CVI | 301 |
CVII | 304 |
CVIII | 307 |
CIX | 309 |
CX | 310 |
CXI | 314 |
CXII | 321 |
CXIII | 325 |
CXIV | 326 |
CXV | 330 |
CXVI | 331 |
CXVIII | 333 |
CXIX | 334 |
CXX | 337 |
CXXI | 339 |
CXXII | 340 |
CXXIII | 343 |
CXXIV | 344 |
CXXV | 346 |
CXXVI | 348 |
CXXVII | 349 |
CXXVIII | 353 |
CXXX | 359 |
CXXXI | 361 |
CXXXII | 362 |
CXXXIII | 364 |
CXXXIV | 373 |
CXXXV | 374 |
CXXXVI | 375 |
CXXXVII | 376 |
CXXXVIII | 380 |
CXXXIX | 385 |
CXL | 386 |
CXLI | 394 |
CXLII | 395 |
CXLIII | 398 |
CXLIV | 407 |
CXLV | 413 |
CXLVII | 416 |
CXLVIII | 420 |
CXLIX | 423 |
CL | 428 |
CLII | 431 |
CLIII | 433 |
CLIV | 437 |
CLV | 439 |
CLVI | 447 |
CLVII | 449 |
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
accuracy acquisition Anadrill analysis annual logging symposium axis barite borehole cable calibration caliper characteristics computed core corresponds counting rates Courtesy of Schlumberger Courtesy of SPWLA curves data quality defined density logging depth matching depth of investigation derived detector device diameter downhole drilling effect environment environmental corrections example filtering fluid formation evaluation ft/h g/cm³ gamma ray geometrical factor Halliburton Logging Services hole input interval invasion laterolog Log Analyst log quality control logging company logging data logging speed logging tool measurement METER method mmho/m modeling mudcake neutron porosity nonconformities ohm-m oil-base mud parameters performed petrophysical precision pressure reference reservoir resistivity sampling rate seismic sensors signal sonde error sonic standard deviation standoff surface systematic error TABLE temperature thermal neutron tool response Trans uncertainty vertical resolution volume water saturation wellsite wireline logging zone
Populāri fragmenti
233. lappuse - RM is defined as a material or substance one or more properties of which are sufficiently well established to be used for the calibration of an apparatus, the assessment of a measurement method, or for assigning values to materials.
46. lappuse - Parameter, associated with the result of a measurement, that characterizes the dispersion of the values that could reasonably be attributed to the measurand.
434. lappuse - ... for practical purposes, the value towards which the average of single results obtained by N laboratories tends, when N becomes very large (Note 5). Consequently, such a true value is associated with the particular method of test employed.
233. lappuse - Set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system, or values represented by a material measure or a reference material, and the corresponding values realized by standards.
233. lappuse - The set of operations which establish, under specified conditions, the relationship between values indicated by a measuring instrument or measuring system, or values represented by a material measure, and the corresponding known values of a reference standard.
343. lappuse - I have made this letter longer than usual, only because I have not had the time to make it shorter.
26. lappuse - ... Planning and Statement of Objectives USEPA has spent considerable effort in developing planning guidance, known as Data Quality Objectives (DQO's) which can be applicable to site assessment planning.(USEPA "Guidance for Data Quality Objective Process," QA/G-4(USEPA, 2000c). This process includes seven steps. - State the problem -Identify the decision -Identify inputs to the decision -Define study boundary areas -Develop a decision rule -Specify decision error limits -Optimize design for obtaining...
107. lappuse - The becquerel is the activity of a radionuclide decaying at the rate of one spontaneous nuclear transition per second. The degree Celsius is equal to the kelvin and is used in place of the kelvin for expressing Celsius temperature (symbol t) defined by the equation / = T - T0 where T is the thermodynamic temperature and T0 = 273.15 K.
Atsauces uz šo grāmatu
Statistical Regression Line-Fitting in the Oil and Gas Industry Richard Woodhouse Priekšskatījums nav pieejams - 2003 |