Demolition Kit, Mine Clearing Line Charge (MICLIC). HIGH EXPLOSIVES Except at time of operation , electrical ... linear charge . ( See para 2-13 for complete rf precautions . ) Ensure that ball lock pin is not in head of rocket at any ...
Demolition Kit, Mine Clearing Line Charge (MICLIC). HIGH EXPLOSIVES Except at time of operation , electrical ... linear charge . ( See para 2-13 for complete rf precautions . ) Ensure that ball lock pin is not in head of rocket at any ...
iii. lappuse
Demolition Kit, Mine Clearing Line Charge (MICLIC). Group 01 Launcher , MK155 MOD O 0101 Launcher Rail ... APPENDIX ... Linear Demolition Charge , M68A2 . Special Tools List F - 40 F - 21 F - 41 F - 21 Section IV APPENDIX G INDEX ...
Demolition Kit, Mine Clearing Line Charge (MICLIC). Group 01 Launcher , MK155 MOD O 0101 Launcher Rail ... APPENDIX ... Linear Demolition Charge , M68A2 . Special Tools List F - 40 F - 21 F - 41 F - 21 Section IV APPENDIX G INDEX ...
1-1. lappuse
... Demolition Kit , Mine Clearing Line Charge ( MICLIC ) . The primary purpose of MICLIC is to clear a safe ... linear demolition charge , launcher , rocket , and technical documentation . 1-4 . PREPARATION FOR STORAGE OR SHIPMENT ...
... Demolition Kit , Mine Clearing Line Charge ( MICLIC ) . The primary purpose of MICLIC is to clear a safe ... linear demolition charge , launcher , rocket , and technical documentation . 1-4 . PREPARATION FOR STORAGE OR SHIPMENT ...
1-2. lappuse
... linear demolition charge ( HE ) will be stored at an Ammunition Supply Point ( ASP ) when not being retained as basic load . The inert M68A2 charge may be kept at the unit level or stored at the ASP , as convenient . Only authorized ...
... linear demolition charge ( HE ) will be stored at an Ammunition Supply Point ( ASP ) when not being retained as basic load . The inert M68A2 charge may be kept at the unit level or stored at the ASP , as convenient . Only authorized ...
1-3. lappuse
... linear charge in 30 minutes . LOCATION AND DESCRIPTION OF MAJOR COMPONENTS . a . External Components . 2 3 1 LINEAR DEMOLITION CHARGE ( M58A3 / M68A2 ) ( 1 ) . Both linear demolition charges , HE and inert , are stored in a linear ...
... linear charge in 30 minutes . LOCATION AND DESCRIPTION OF MAJOR COMPONENTS . a . External Components . 2 3 1 LINEAR DEMOLITION CHARGE ( M58A3 / M68A2 ) ( 1 ) . Both linear demolition charges , HE and inert , are stored in a linear ...
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
9/16-inch combination box appendix F arresting cable fuze B-nut Bleed Hydraulic System bridle cable cable fuze connector check valve clevis pins clinometer column CONT control valve handle control valve lever cotter pin damage demolition charge container detent assembly detonators Disconnect elbow electrical lead Ensure flatwashers fluid dampener hand knobs hand pump hex key hex nuts hook hydraulic control valve hydraulic cylinder hydraulic fluid hydraulic hose INITIAL SETUP Tools inserting ball-lock pins Inspect Install intermediate direct support item 12 lanyard launch launcher rail supports lifting sling linear charge linear demolition charge lockwashers M34 blasting machine maintenance Materials/Parts mechanic's tool MICLIC open-end wrench operation paint PAOZZ personnel PMCS PROCEDURES protective cap Pull pump handle rear receptacle RELEASE position release valve handle repacked repair rocket bands rocket motor safety switch assembly Screw socket wrench storage container street elbow task covers tighten tool kit item Tools General mechanic's towing vehicle U-bolts Unscrew