Operator's, Unit, Intermediate Direct Support, and Intermediate General Maintenance Manual Including Repair Parts and Special Tools List: Demolition Kit, Mine Clearing Line Charge (MICLIC).Headquarters, Department of the Army, 1986 |
No grāmatas satura
1.–5. rezultāts no 69.
i. lappuse
... Checks and Services ( PMCS ) ... Section ||| Operation Under Usual Conditions Section IV Operation Under Unusual Conditions CHAPTER 3 OPERATOR MAINTENANCE .. Section I Lubrication Instructions Section II Troubleshooting Procedures ...
... Checks and Services ( PMCS ) ... Section ||| Operation Under Usual Conditions Section IV Operation Under Unusual Conditions CHAPTER 3 OPERATOR MAINTENANCE .. Section I Lubrication Instructions Section II Troubleshooting Procedures ...
iv. lappuse
... checks and services , and operating under usual and unusual conditions . C. Chapter 3 , Operator Maintenance . Explains the operator's responsibilities for main- taining the Mine Clearing Line Charge . d . Chapter 4 , Unit Maintenance ...
... checks and services , and operating under usual and unusual conditions . C. Chapter 3 , Operator Maintenance . Explains the operator's responsibilities for main- taining the Mine Clearing Line Charge . d . Chapter 4 , Unit Maintenance ...
1-5. lappuse
... check continuity throughout the electrical system . The cotter pins are not used with current line charges and may be discarded . ROCKET HARNESS CONNECTOR . The rocket harness connector is attached to the head end of the linear ...
... check continuity throughout the electrical system . The cotter pins are not used with current line charges and may be discarded . ROCKET HARNESS CONNECTOR . The rocket harness connector is attached to the head end of the linear ...
1-6. lappuse
... check valve when the accumulator is being charged . ( c ) REMOTE RAISE . The hydraulic control valve can be moved from the PRESSURIZE AC- CUMULATOR position to the REMOTE RAISE position by pulling the lanyard from inside the tow vehicle ...
... check valve when the accumulator is being charged . ( c ) REMOTE RAISE . The hydraulic control valve can be moved from the PRESSURIZE AC- CUMULATOR position to the REMOTE RAISE position by pulling the lanyard from inside the tow vehicle ...
1-13. lappuse
... Check all electrical connections to linear charge for proper assembly . Correct problems immediately . Repeat firing sequence . ( 5 ) If no fire still , wait 30 minutes in case of hangfire . ( 6 ) Remove linear charge electrical lead ...
... Check all electrical connections to linear charge for proper assembly . Correct problems immediately . Repeat firing sequence . ( 5 ) If no fire still , wait 30 minutes in case of hangfire . ( 6 ) Remove linear charge electrical lead ...
Citi izdevumi - Skatīt visu
Bieži izmantoti vārdi un frāzes
9/16-inch combination box appendix F arresting cable fuze B-nut Bleed Hydraulic System bridle cable cable fuze connector check valve clevis pins clinometer column CONT control valve handle control valve lever cotter pin damage demolition charge container detent assembly detonators Disconnect elbow electrical lead Ensure flatwashers fluid dampener hand knobs hand pump hex key hex nuts hook hydraulic control valve hydraulic cylinder hydraulic fluid hydraulic hose INITIAL SETUP Tools inserting ball-lock pins Inspect Install intermediate direct support item 12 lanyard launch launcher rail supports lifting sling linear charge linear demolition charge lockwashers M34 blasting machine maintenance Materials/Parts mechanic's tool MICLIC open-end wrench operation paint PAOZZ personnel PMCS PROCEDURES protective cap Pull pump handle rear receptacle RELEASE position release valve handle repacked repair rocket bands rocket motor safety switch assembly Screw socket wrench storage container street elbow task covers tighten tool kit item Tools General mechanic's towing vehicle U-bolts Unscrew