Operator's Manual for Trainer, Unit-conduct of Fire (U-COFT), M1A1-120mm Tank (sheltered), 60 Hz (6920-01-158-2638), 50 Hz (6920-01-158-2639).Headquarters, Department of the Army, 1988 |
No grāmatas satura
1.–5. rezultāts no 52.
iii. lappuse
... Step 6 unless lamp is properly seated . INTERNAL REFERENCING Referencing within this manual is done by page number . Example : Reference to Mode Selection Display page ( see 2-42 ) refers you to Chapter 2 page 42 of this manual ...
... Step 6 unless lamp is properly seated . INTERNAL REFERENCING Referencing within this manual is done by page number . Example : Reference to Mode Selection Display page ( see 2-42 ) refers you to Chapter 2 page 42 of this manual ...
2-126. lappuse
... step 3 ; otherwise , refer to Unusual Electronic Equipment Power - Up Procedure ( see 2-218 ) . In Computer Shelter , open the door of Electronics Power Distribution Panel and make sure main circuit breaker ( 2 ) and seven subcircuit ...
... step 3 ; otherwise , refer to Unusual Electronic Equipment Power - Up Procedure ( see 2-218 ) . In Computer Shelter , open the door of Electronics Power Distribution Panel and make sure main circuit breaker ( 2 ) and seven subcircuit ...
2-128. lappuse
... step . If not off , press RUN / STOP pushbutton indicator and wait for indicators to go off . NOTE If the FAULT pushbutton indicator ( 16 ) lights , notify organizational maintenance . AUTO RESTART OFF ON RUN POWER REMOTE BOOT TT ( 12 ) ...
... step . If not off , press RUN / STOP pushbutton indicator and wait for indicators to go off . NOTE If the FAULT pushbutton indicator ( 16 ) lights , notify organizational maintenance . AUTO RESTART OFF ON RUN POWER REMOTE BOOT TT ( 12 ) ...
2-132. lappuse
... STEP - NONE , CLOCK - NORM RAD - HEX , ADD - PHYS , DAT - LONG , FILL - 00 , REL - 00000000 INIT SEQ DONE 10 HALTED AT 00000000 10 1 ( RELOADING WCS ) 10 LOAD DONE.XXXX MICROWORDS LOADED 1 44 VER : PCS - XX WCS - XXXXX FPLA - XX CON ...
... STEP - NONE , CLOCK - NORM RAD - HEX , ADD - PHYS , DAT - LONG , FILL - 00 , REL - 00000000 INIT SEQ DONE 10 HALTED AT 00000000 10 1 ( RELOADING WCS ) 10 LOAD DONE.XXXX MICROWORDS LOADED 1 44 VER : PCS - XX WCS - XXXXX FPLA - XX CON ...
2-134. lappuse
... step 34 . 36 . In Computer Shelter , at GPC Main Cabinet Control Console , set keyswitch ( 10 ) to LOCAL DISABLE position . 37 . NOTE For power - up of the Remote Monitor Station ( RMS ) see 2-135 . To continue operation , perform User ...
... step 34 . 36 . In Computer Shelter , at GPC Main Cabinet Control Console , set keyswitch ( 10 ) to LOCAL DISABLE position . 37 . NOTE For power - up of the Remote Monitor Station ( RMS ) see 2-135 . To continue operation , perform User ...
Bieži izmantoti vārdi un frāzes
Acquisition and Manipulation Air Conditioner APFSDS appears correctly AUTO Boresight circuit breaker COAX Commander Commander's Computer Recommendation Computer Shelter control and overload Control or Indicator Crew Station DC POWER SUPPLIES Defilade DEGAUSS display page DISPLAY TERMINAL PAGES Enter Number Exercise Running Exercise Select Exercise Select/Session Summary fire Freeze Gunner GUNR Indicator Function indicator lamp Instructor/Operator Integration Shelter IOS DISPLAY TERMINAL Key Control key is pressed key on keyboard Keypad Options light Manual Pull Station MIAI U-COFT Mode Select NORMAL NORMAL ANTHONY notify Organizational Maintenance Observe On/off control performance power-up Press number Press RETURN key pressing the RETURN PRINT printout PROCEDURE Continued prompt pushbutton RAPID NORMAL NORMAL Ret Aim SABOT T72 WHOLE Select by Content Session Summary SNGL TGT STN SPECIAL PURPOSE COMPUTER Status switch Tank Target Target Target TERMINAL PAGES EXERCISE Terminal Printer Trainer Shelter Training Management System Training Session Initialization vehicle name volt