Operator's Manual for Trainer, Unit-conduct of Fire (U-COFT), M1A1-120mm Tank (sheltered), 60 Hz (6920-01-158-2638), 50 Hz (6920-01-158-2639).Headquarters, Department of the Army, 1988 |
No grāmatas satura
1.–5. rezultāts no 23.
1-42. lappuse
... pushbutton ( 11 ) , but the the over- temperature light will remain on until the problem is corrected . TEST pushbutton ( 12 ) allows the Instructor / Operator to test the buzzer to verify that it is operable . Additional ...
... pushbutton ( 11 ) , but the the over- temperature light will remain on until the problem is corrected . TEST pushbutton ( 12 ) allows the Instructor / Operator to test the buzzer to verify that it is operable . Additional ...
1-43. lappuse
... push- button switches ( 8 ) , ( 9 ) , and ( 10 ) are located on the walls of the Computer and Trainer Shelters . 10 9 5 2 1 6 8 3 7 LIGHTING Each shelter is provided with normal and emergency lighting 1-43 TM 9-6920-740-10.
... push- button switches ( 8 ) , ( 9 ) , and ( 10 ) are located on the walls of the Computer and Trainer Shelters . 10 9 5 2 1 6 8 3 7 LIGHTING Each shelter is provided with normal and emergency lighting 1-43 TM 9-6920-740-10.
2-1. lappuse
... pushbutton switch EMERGENCY POWER OFF pushbutton switch When pressed , trips main circuit breakers in Shelter Power Distribution Panels and turns off all ac power in Shelters . Same as ( 1 ) 3 EMERGENCY POWER OFF pushbutton switch Same ...
... pushbutton switch EMERGENCY POWER OFF pushbutton switch When pressed , trips main circuit breakers in Shelter Power Distribution Panels and turns off all ac power in Shelters . Same as ( 1 ) 3 EMERGENCY POWER OFF pushbutton switch Same ...
2-13. lappuse
... pushbutton matic shut down by a low or high pressure condition in the freon system . 5 Five Position MODE 6 7 8 9 10 SELECTOR SWITCH : - OFF - STANDBY - VENT - COOL - HEAT CONTROL CIRCUIT BREAKER pushbutton switch LOW WATER LEVEL ...
... pushbutton matic shut down by a low or high pressure condition in the freon system . 5 Five Position MODE 6 7 8 9 10 SELECTOR SWITCH : - OFF - STANDBY - VENT - COOL - HEAT CONTROL CIRCUIT BREAKER pushbutton switch LOW WATER LEVEL ...
2-16. lappuse
... pushbutton indicator Function On / off control for the Disk Drive . When pushed in , the disk begins turning and the ... pushbutton TERMINAL PRINTER 1 2 מעננער . 3 2-16 TM 9-6920-740-10.
... pushbutton indicator Function On / off control for the Disk Drive . When pushed in , the disk begins turning and the ... pushbutton TERMINAL PRINTER 1 2 מעננער . 3 2-16 TM 9-6920-740-10.
Bieži izmantoti vārdi un frāzes
Acquisition and Manipulation Air Conditioner APFSDS appears correctly AUTO Boresight circuit breaker COAX Commander Commander's Computer Recommendation Computer Shelter control and overload Control or Indicator Crew Station DC POWER SUPPLIES Defilade DEGAUSS display page DISPLAY TERMINAL PAGES Enter Number Exercise Running Exercise Select Exercise Select/Session Summary fire Freeze Gunner GUNR Indicator Function indicator lamp Instructor/Operator Integration Shelter IOS DISPLAY TERMINAL Key Control key is pressed key on keyboard Keypad Options light Manual Pull Station MIAI U-COFT Mode Select NORMAL NORMAL ANTHONY notify Organizational Maintenance Observe On/off control performance power-up Press number Press RETURN key pressing the RETURN PRINT printout PROCEDURE Continued prompt pushbutton RAPID NORMAL NORMAL Ret Aim SABOT T72 WHOLE Select by Content Session Summary SNGL TGT STN SPECIAL PURPOSE COMPUTER Status switch Tank Target Target Target TERMINAL PAGES EXERCISE Terminal Printer Trainer Shelter Training Management System Training Session Initialization vehicle name volt