Operator's Manual for Trainer, Unit-conduct of Fire (U-COFT), M1A1-120mm Tank (sheltered), 60 Hz (6920-01-158-2638), 50 Hz (6920-01-158-2639).Headquarters, Department of the Army, 1988 |
No grāmatas satura
1.–5. rezultāts no 55.
1-5. lappuse
... Light Amplification by S Speed Stimulated Emission of SABOT Radiation LG Long Range Armor - Piercing , Fin Stabi- lized , Discarding Sabot ( APFSDS ) Ammunition LRF Laser Rangefinder SAGGER SEC Soviet Antitank Missile Seconds SIM MALF ...
... Light Amplification by S Speed Stimulated Emission of SABOT Radiation LG Long Range Armor - Piercing , Fin Stabi- lized , Discarding Sabot ( APFSDS ) Ammunition LRF Laser Rangefinder SAGGER SEC Soviet Antitank Missile Seconds SIM MALF ...
1-19. lappuse
... light , CKT BKR OPEN light , ENGINE FIRE light , AIR TEMP control , and NBC ALARM NBC ALARM MUTE control are not functional in the MIAI U - COFT . However , the lamps will light when lamp tested . Intercom control and frequency selector ...
... light , CKT BKR OPEN light , ENGINE FIRE light , AIR TEMP control , and NBC ALARM NBC ALARM MUTE control are not functional in the MIAI U - COFT . However , the lamps will light when lamp tested . Intercom control and frequency selector ...
1-20. lappuse
... Light Ballistic Door Handles Intercom System EMERGENCY GUNNERY MODE SIMULATION Muzzle Reference Sensor Misalignment Laser Range Finder Failure Lead Angle / Rate Sensor Failure Main Gun Stabilization Failure Ballistic Computer Complete ...
... Light Ballistic Door Handles Intercom System EMERGENCY GUNNERY MODE SIMULATION Muzzle Reference Sensor Misalignment Laser Range Finder Failure Lead Angle / Rate Sensor Failure Main Gun Stabilization Failure Ballistic Computer Complete ...
1-28. lappuse
... lights adjust and test , fire control mode select , normal mode drift adjust , ammunition select , filter select and magnification . TIS control panel , thermal magnifi- cation , and focus . LRF RANGE switch panel . Ballistic computer ...
... lights adjust and test , fire control mode select , normal mode drift adjust , ammunition select , filter select and magnification . TIS control panel , thermal magnifi- cation , and focus . LRF RANGE switch panel . Ballistic computer ...
1-39. lappuse
... an alarm horn ( 5 ) and flashes a strobe light ( 6 ) in the Crew Station if smoke or high temperatures are present in the Shelters . 2 3 3 숭 op 1 2 1 2 5 4 3 In addition to the alarms , a fire control agent. 1-39 TM 9-6920-740-10.
... an alarm horn ( 5 ) and flashes a strobe light ( 6 ) in the Crew Station if smoke or high temperatures are present in the Shelters . 2 3 3 숭 op 1 2 1 2 5 4 3 In addition to the alarms , a fire control agent. 1-39 TM 9-6920-740-10.
Bieži izmantoti vārdi un frāzes
Acquisition and Manipulation Air Conditioner APFSDS appears correctly AUTO Boresight circuit breaker COAX Commander Commander's Computer Recommendation Computer Shelter control and overload Control or Indicator Crew Station DC POWER SUPPLIES Defilade DEGAUSS display page DISPLAY TERMINAL PAGES Enter Number Exercise Running Exercise Select Exercise Select/Session Summary fire Freeze Gunner GUNR Indicator Function indicator lamp Instructor/Operator Integration Shelter IOS DISPLAY TERMINAL Key Control key is pressed key on keyboard Keypad Options light Manual Pull Station MIAI U-COFT Mode Select NORMAL NORMAL ANTHONY notify Organizational Maintenance Observe On/off control performance power-up Press number Press RETURN key pressing the RETURN PRINT printout PROCEDURE Continued prompt pushbutton RAPID NORMAL NORMAL Ret Aim SABOT T72 WHOLE Select by Content Session Summary SNGL TGT STN SPECIAL PURPOSE COMPUTER Status switch Tank Target Target Target TERMINAL PAGES EXERCISE Terminal Printer Trainer Shelter Training Management System Training Session Initialization vehicle name volt