(2) License agreement. Each administrator shall have a written license agreement with each participating manufacturer binding each to the provisions of the specific program and authorizing the manufacturer to use the administrator's mark, seal, or label on its products. The administrator shall have the right to terminate any agreement prior to an expiration date, for example, if there has been a breach of the requirement of the certification program by the manufacturer.

(3) Laboratory approval. The administrator shall review laboratories that apply for participation in this program on the basis of the procedures described in paragraph (e) of this section. A list of approved laboratories shall be maintained by the administrator. When the certification program allows the use of the administrator's testing laboratories, the laboratories shall be reviewed by a qualified party acceptable to HUD. As accreditation procedures are made available through the National Voluntary Laboratory Accreditation Program (NVLAP) for specifc products, HUD may require such accreditation.

(4) Initial testing and quality control review—(i) Initial testing. Each participating manufacturer shall submit to the appropriate administrator, the product(s) specification and statement(s) that the product complies with the applicable standard. The administrator shall select samples of the product(s), or when HUD specifies as acceptable, a prototype. The particular method of sample selection shall be determined by HUD for each specific product certification program. Other methods of initial sample selection may be used if deemed necessary. If a failure occurs on the initial tests, additional sampling and testing may be done at the manufacturer's request. The administrator's validation of the manufacturer's declaration of certification shall be withheld until a finding of compliance is achieved.

(ii) Quality assurance system review. (A) Each administrator shall examine a participating manufacturer's facilities and quality assurance system procedures to determine that they are adequate to assure continuing production of the product that complies with the

applicable standard. These quality assurance system procedures shall be documented in the administrator's and the manufacturer's files. If a manufacturer's quality assurance system is not satisfactory to the administrator, validation of the manufacturer's declaration of certification shall be withheld. The following American Society for Quality Control (ASQC) standards, which are incorporated by reference, may be used as guidelines in any quality assurance review:

(1) ASQC Q9000-1-1994 Quality Management and Quality Assurance Standards Guidelines for Selection and Use;

(2) ASQC Q9001-1994 Quality Systems-Model for Quality Assurance in Design, Development, Production, Installation, and Servicing;

(3) ASQC Q9002-1994 Quality Systems-Model for Quality Assurance in Production, Installation, and Servicing;

(4) ASQC Q9003-1994 Quality Systems-Model for Quality Assurance in Final Inspection and Test;

(5) ASQC Q9004-1-1994 Quality Management and Quality System Elements-Guidelines.

(B) These standards have been approved by the Director of the Federal Register for incorporation by reference in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. They are available from the American Society for Quality Control (ASQC), 611 East Wisconsin Avenue, Milwaukee, WI 53202.

(5) Notice of validation. When initial testing, quality control review, and evaluation of other technical data are satisfactory to the administrator, a Notice of Validation or Certification shall be issued to the manufacturer. This allows the use of the administrator's registered mark on the product label.

(6) Labeling. Each administrator shall issue to the manufacturer labels, tags, marks containing the administrator's validation mark, and the manufacturer's certification of compliance with the applicable standard. The registered administrator's (validator's) mark shall be on the label. A sponsor's (association, testing agencies, society or others) mark may be used in addition to the administrator's mark. The manufacturer's certification of compliance

to the standard may be coded. Additional information such as type, grade, class, etc., may also be coded. When coding is used, the code shall be described in the directory or listing.

(7) Directory or listing. When required by the program, the administrator shall publish a directory or listing for all certified products. The directory shall list the items described in paragraph (d)(6) of this section. The directly shall also carry a complete list of approved laboratories and shall be updated to reflect additions or deletions of certified products and laboratories. Directories or listings shall be published periodically as described in the specific program. Each administrator shall make a complimentary distribution of the directory or listing to the HUD Field Offices and other government agencies designated by HUD. A subscription fee may be charged to others requesting copies.

(8) Periodic tests and quality control inspections. Samples of the certified product or prototype shall be selected periodically from the plant, warehouse inventory or sales points. The samples shall be sent to an administrator-approved laboratory and tested in accordance with the applicable standard. The frequency of testing shall be described in the specific building product program. The administrator shall periodically visit the manufacturer's facility to assure that the initially accepted quality control procedures are being followed.

(9) Product decertification. If a failure should occur in any test, the laboratory shall notify the administrator and the manufacturer. The manufacturer shall notify the administrator if a retest if requested. If a retest is not requested, validation shall be withdrawn. If the manufacturer requests a retest, the administrator shall select new samples and submit them to the same or another laboratory at the manufacturer's expense, for retest of only the test requirement(s) in which the failure(s) occurred. If the specified number of specimens pass the retest, the product can continue to be validated and listed. If the designated number of specimens described in the UM Bulletin fail, the administrator shall decertify the product. The manufacturer may re

quest that a new selection be made of the product after corredction or modifications and be subjected to the initial acceptance testing procedure or to a program of retesting established by the administrator. The administrator may decertify the product on the basis of inadequate quality control by the manufacturer. The administrator shall notify the manufacturer, HUD headquarters and the HUD Field Offices of any decertification within 7 days. When the product is decertified the maqnufacturer shall remove labels, tags or marks from all production and inventory in his/her control determined to be in noncompliance.

(10) Challenge response. Any person or organization may submit a sample of a manufacturer's certified product to the administrator in substantiation of a claim of noncompliance. Submission shall be made to the administrator that validated the manufacturer's product. The administrator shall notify the manufacturer that its product has been challenged and shall make arrangements to obtain test samples of the challenged product. An estimate of the cost of the special sample selection and testing shall be made to the complainant. The complainant shall pay the estimated cost of the investigation in advance of any testing of the challenged product, unless HUD believes the complaint to be in the public's interest. HUD may conduct its own investigation when deemed necessary based upon a complaint or a product failure. The administrator shall submit the sample of the challenged product to an approved laboratory of the administrator's choice with the request to test compliance of only the challenged requirement(s). If the samples tested prove that the product failed to meet the standard, the product shall be decertified immediately. The manufacturer whose product is decertified shall reimburse the administrator for all costs of the investigation and the administrator shall refund the complainant's advance payment. If the tests prove that the product does comply with the standard, the complainant shall be notified that the tests do not support the complaint and that the advance fee has been used for the cost of testing and investigating the claim.

(11) Maintainance of the program. Each administrator shall maintain the program in conformance with administrative letters issued by HUD for the purpose of clarifying procedures and interpreting the applicable standard. These letters may also be used to revise and amend the procedures used in specific programs. Significant changes in any program shall be published in the FEDERAL REGISTER.

(e) Laboratory qualifications. The following laboratory qualifications apply to all testing laboratories participating in the program including manufacturer's laboratories and the administrator's own laboratories when designated in the specific program.

(1) Organization and personnel. Laboratories wishing to participate in a certification program shall apply to the administrator and shall furnish the following information:

(i) Name of laboratory, address, telephone number, name and title of official to be contacted for this program.

(ii) Name and qualifications of person assigned by the laboratory to supervise testing under a specific certification program.

(iii) Name and qualifications of engineers and other key personnel who shall conduct the testing.

(iv) Brief review of training program for personnel associated with program to assure the operational efficiency and uniformity of the testing and quality control procedures.

Each laboratory shall notify the administrator of any change in its submission regarding procedures and/or major personnel associated with the program.

(2) Equipment and facilities. Each laboratory shall:

(i) Describe the test instruments and testing facilities to be used in making the test(s) required by the applicable standard. Information shall include: Item of equipment, manufacturer, type or model, serial number, range, precision, frequency of calibration and dates of calibration.

(ii) Provide photographs of the listed equipment.

(iii) Provide a description of the applicable standards and calibration equipment being used and the calibration procedures followed, including Na

tional Bureau of Standards traceability, when applicable. List outside organizations providing calibration services, if used.

(iv) Demonstrate that measurements can be made with existing equipment and repeated precision within the limits established by the applicable standards. Administrator may periodically require laboratories to conduct collaborative testing on standard reference materials.

(v) Provide evidence, when regulated temperatures and humidity are required, that charts are maintained from a continuous recorder registering both wet and dry bulb temperature or relative humidity. The charts are to be properly dated, retained and available for inspection.

(vi) Provide a list of standards, test methods and other information necessary to carry out the program.

(3) Testing methodology. (i) Describe concisely the procedures for conducting the tests required and the specific equipment to be used.

(ii) Attach a sample test report showing representative test results and accompanied by test data forms for each test required. When approved for program participation, testing laboratories may be required by administrator to report test results on standard summary report forms.

(4) Subcontractors. If a testing laboratory plans to subcontract any of its testing to other laboratories, only approved laboratories acceptable to the administrator shall be used.

(5) Laboratory quality control. The laboratory shall develop operating quality control procedures acceptable to the administrator. The procedures of the American Council of Independent Laboratories1 may be used as a guideline.

(6) Approval of laboratories. Administrators shall develop detailed laboratory approval requirements and conduct periodic inspections to assure each test laboratory's capability. Laboratory approval may be granted for 2 years. Reapproval of the laboratory shall be necessary every 2 years. When

1 Copies are available from the American Council of Independent Laboratories, Inc., 1725 "K" Street, NW., Washington, DC 20006.

a program allows the use of an administrator's own laboratories, these laboratories shall be reviewed by a qualified third party acceptable to HUD. Documentation of acceptance for administrator laboratories shall be maintained by the administrator and HUD. Administrator laboratories shall be subject to reapproval every two years.

(7) Withdrawal of approval. Laboratory approval shall be withdrawn or temporarily suspended if it is determined that the laboratory is not complying with the approved requirements. Causes for suspension include, but are not limited to, the following:

(i) Incompetence.

(ii) Failure to test in accordance with the test methods described in the standard.

(iii) Issuance of test reports which fail to comply with the requirements described in the specific product certification program.

(iv) Falsification of the information reported.

(v) A statement implying validation of the product using a test report which constitutes only part of the total standard.

(vi) Deceptively utilizing references in advertising or other promotional activities.

(vii) Submission of incomplete or inadequate information and documentation called for herein.

[44 FR 54656, Sept. 20, 1979, as amended at 63 FR 5423, Feb. 2, 1998]

§200.936 Supplementary specific procedural requirements under HUD building products certification program for solid fuel type room heaters and fireplace stoves.

(a) Applicable standards. Solid fuel type room heaters and fireplace stoves certified under the HUD Building Products Certification Program shall be designed, assembled and tested in conformance with the following standards, which are incorporated by reference:

(1) ANSI/UL 737 (1978), for fireplace stoves;

(2) ANSI/UL 1482 (1979), for solid fuel type room heaters with coal amendments.

of

(b) Labelling. (1) Under the procedures set forth in paragraph (d)(6) of §200.935, concerning labelling of a product, the administrator's validation mark and the manufacturer's certification compliance with the applicable standards are required to be on the certification label issued by the administrator to the manufacturer. In the case of solid fuel type room heaters and fireplace stoves, the following additional information must be included on the certification label:

(i) The manufacturer's statement of conformance to the HUD Building Products Certification Program;

(ii) The manufacturer's name and the identity and location of manufacturing plant;

(iii) The specification designation and manufacturer series or model number; and

(iv) The type of fuel to be used.

(2) The certification label must be permanently affixed to the heater or stove and be readily visible after the heater or stove is installed.

(c) Periodic tests and quality control inspections. Under the procedures set forth in paragraph (d)(8) of $200.935, concerning periodic tests and quality control inspections, the frequency of testing for a product must be described in the specific building product certification program. In the case of solid fuel type room heaters and fireplace stoves, testing and inspection shall be conducted as follows:

(1) Once every four years, beginning with the initial administrator visit, a sample of each certified product shall be selected by the administrator for testing for compliance with the applicable standards in a laboratory which has been accredited under the National Voluntary Laboratory Accreditation Program.

(2) The administrator shall visit the manufacturer's facility two times a year to assure that the initially accepted quality control procedures are being followed.

[48 FR 1955, Jan. 17, 1983]

[blocks in formation]

(2) These standards have been approved by the Director of the Federal Register for incorporation by reference. They are available from the American National Standards Institute, Inc., 11 West 42nd Street, New York, NY 10036. The standards are also available for inspection at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington DC 20408.

(b) Labeling. (1) Under the procedures set forth in paragraph (d)(6) of § 200.935, concerning labeling of a product, the administrator's validation mark and the manufacturer's certification of compliance with the applicable standards are required to be on the certification label issued by the administrator to the manufacturer. In the case of plastic bathtub units, plastic shower receptors and stalls, plastic lavatories, and plastic water closet bowls and tanks, the following additional information shall be included on the certification label:

(i) Manufacturer's statement of conformance to UM 73a;

(ii) Manufacturer's name and code identifying the plant location.

(2) The certification label shall be affixed to each plastic bathroom fixture.

(c) Periodic tests and quality control inspections. Under the procedures set forth in paragraph (d)(8) of §200.935, concerning periodic tests and quality control inspections, the frequency of testing for a product shall be described

in the specific building product certification program. In the case of plastic bathroom fixtures, testing and inspection shall be conducted as follows:

(1) At least every six months, the administrator shall visit the manufacturer's facility to select a sample of each certified plastic bathtub unit, plastic shower receptor and stall, plastic water closet bowl and tank for testing in an approved laboratory, in in accordance with applicable standards.

(2) At least every twelve months, the administrator shall visit the manufacturer's facility to select a sample of each certified plastic lavatory for testing in accordance with applicable standards.

(3) The administrator shall also review quality control procedures at each visit to determine that they continue to be followed.

[49 FR 378, Jan. 4, 1984, as amended at 59 FR 36695, July 19, 1994]

§ 200.940 Supplementary specific requirements under the HÚD building product standards and certification program for sealed insulating glass units.

(a) Applicable standards. (1) All sealed insulating glass units shall be designed, manufactured, and tested in compliance with the American Society for Testing and Materials standard: ASTM E-774-92 Standard Specification for Sealed Insulating Glass Units.

(2) This standard has been approved by the Director of the Federal Register for incorporation by reference. The standard is available from the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103. This standard is also available for inspection at the Office of the Federal Register, 800 North Capitol Street, NW., 7th Floor, suite 700, Washington, DC.

(b) Labeling. Under the procedures set forth in §200.935(d)(6) concerning labeling of a product, the administrator's validation mark and the manufacturer's certification of compliance with the applicable standards are issued by the administrator to the manufacturer. Each sealed insulating glass unit shall be marked as conforming to UM 82a. The label shall be located on each sealed insulating unit so that it is