Operator, Organizational, Direct Support, and General Support Maintenance Manual (including Repair Parts and Special Tools List) for Alinement Device, M139 (4931-01-048-5834) and Alinement Device with Case, M140 (4931-01-187-9713).Headquarters, Department of the Army, 1991 |
No grāmatas satura
1.–5. rezultāts no 13.
iv. lappuse
... Lens fogged or con- densation present No illumination Illuminated , but no reticle pattern Cleaning Compound Item 4 , Appendix D TM 9-254 Enamel Item 5 , Appendix D TM 750-116 General Safety Instructions : Grease Item 6 , Appendix D ...
... Lens fogged or con- densation present No illumination Illuminated , but no reticle pattern Cleaning Compound Item 4 , Appendix D TM 9-254 Enamel Item 5 , Appendix D TM 750-116 General Safety Instructions : Grease Item 6 , Appendix D ...
13. lappuse
... Lens , Optical Optical Retainer Optical Cell Assembly ... . Lens , Optical ..Valve Cap Strap Purging Valve Stem Lever Objective Cell Assembly Objective Lens . Retainer , Ring Reticle Cell Assembly Reticle Lens .... Strap ... b . Valve ...
... Lens , Optical Optical Retainer Optical Cell Assembly ... . Lens , Optical ..Valve Cap Strap Purging Valve Stem Lever Objective Cell Assembly Objective Lens . Retainer , Ring Reticle Cell Assembly Reticle Lens .... Strap ... b . Valve ...
15. lappuse
... lenses are located in this assembly . ( 2 ) Valve Stem ( 2 ) . The valve stem is the at- tachment point for the nitrogen purging hose . ( 3 ) Bleed Screw ( 3 ) . Outlet port for purged nitrogen . 3 2 ( 4 ) Base ( 4 ) . Mounting point ...
... lenses are located in this assembly . ( 2 ) Valve Stem ( 2 ) . The valve stem is the at- tachment point for the nitrogen purging hose . ( 3 ) Bleed Screw ( 3 ) . Outlet port for purged nitrogen . 3 2 ( 4 ) Base ( 4 ) . Mounting point ...
5-3. lappuse
... LENS CELL Place instrument in a dark area , allowing edges to adjust for approximately 15 minutes . Check that light is visible . Check that cell is not cracked , chipped , scratched , or missing . PURGING VALVE Check that valve is ...
... LENS CELL Place instrument in a dark area , allowing edges to adjust for approximately 15 minutes . Check that light is visible . Check that cell is not cracked , chipped , scratched , or missing . PURGING VALVE Check that valve is ...
5-4. lappuse
... Lens fogged or condensation present . No illumination .... Illuminated , but no reticle pattern Troubleshooting Procedure ( Page ) 5-5 5-5 5-5 .. 5-6 5-3 GENERAL CONTINUED Table 5-2 . TROUBLESHOOTING MALFUNCTION TEST OR 5-4 TM 9-4931 ...
... Lens fogged or condensation present . No illumination .... Illuminated , but no reticle pattern Troubleshooting Procedure ( Page ) 5-5 5-5 5-5 .. 5-6 5-3 GENERAL CONTINUED Table 5-2 . TROUBLESHOOTING MALFUNCTION TEST OR 5-4 TM 9-4931 ...
Bieži izmantoti vārdi un frāzes
3rd position 5-8 COLLIMATION ALINEMENT DEVICE MAINTENANCE AMSMC-MAS ROCK ISLAND Army Armament AZIMUTH TEST FIXTURE BORESIGHT BUSINESS REPLY MAIL C-3 EXPLANATION cap assembly Centimeters CHEMICAL COMMAND ATTN COLLIMATION AND INSPECTION collimation standard collimator 9 COLUMNS SECTION components Depot Maintenance DESCRIPTION AND USABLE DEVICE MAINTENANCE INSTRUCTIONS dial indicator Disassembly dovetail END OF FIGURE EXPLANATION OF COLUMNS Field Maintenance Fluid Ounces infinity collimator Install Instrument and Fire item number Kilopascals M139/M140 ALINEMENT DEVICE M139& Alinement M140 Alinement Device maintenance code maintenance function MAINTENANCE INSTRUCTIONS CONTINUED Maintenance Manual Maintenance Repair Materials/Parts Materiel Meters MUNITIONS AND CHEMICAL National Stock Number NUMBER INDEX Objective Cell Assembly objective lens OPTICAL CELL ASSEMBLY packing PAHZZ PAOZZ plate projector collimator Reassembly Remove Replace retaining ring Reticle Cell Assembly screws sealing compound Item Self-Propelled sharpening stone Short Tons SMR code source code Special Tools List spot seal Support Maintenance tritium troubleshooting U.S. Army USABLE ON CODES V-block